Using The Wireless Remote Control System
EIO0000001505 12/2014
125
START
Overview
The START mode is the only mode in which:
You can command the motions
.
You can command the auxiliary function
You can command the horn
.
The safety relays are switched ON.
Triggering Procedure
Required conditions: The Wireless Remote Control System must be in STOP mode.
Triggering procedure:
START Details
It is recommended to use a Schneider Electric beacon:
1
Light wired to the “Radio link” relay
2
Light wired to the “Safety relay image” relay
3
Buzzer wired to the “Horn” relay (an additional flash light can be wired to this relay)
Step
Action
1
If a START code sequence is configured:
Type the START code sequence with the motion buttons 1, 2, 3, 4, 5, 6.
The default START code sequence is 5, 6, 5, 6.
Press the button 7 (trigger) to validate.
2
Press only the ON/START/Horn button more or equal than 1 s.
3
Wait during the START warning time (ZART•D vibrations, “Horn” relay ON).