eXLhoist Configuration Software
192
EIO0000001505 12/2014
Identification Setting
You can select the Wireless Remote Control System configuration between:
SINGLE
TANDEM
You must enter the Base Station ID:
Format: 00 80 F4 0X XX XX (0X XX XX is an hexadecimal value from 0 00 00 to 3 FF FF).
This ID can be read on the Base Station.
Click
Label
checkbox to enable the label management. Select in the listbox a label number
(0…999). This label number is displayed on the ZART•D to identify the selected Base
Station/Bridge.
Start Access Sequence
The START access sequence is optional.
When START access sequence is enabled, the operator MUST enter this sequence to go in
START mode.
The START access sequence is enabled by default.
The default START access sequence is: 5, 6, 5, 6.
Click
Enable
checkbox to enable/disable it.
The allowed buttons for this sequence are 1, 2, 3, 4, 5, 6.
The sequence can have 1 to 6 steps.
Access sequence can use same button several times. For example: step 1 = 3 and step 4 = 3.
E-STOP RESET Sequence
The E-STOP RESET sequence is optional.
E-STOP RESET sequence is asked to the operator to reset the Remote Device after an E-STOP.
If reset sequence is empty or disable, the operator has to press the button 7 (trigger).
Click
Enable
checkbox to enable/disable it.
The allowed buttons for this sequence are 1, 2, 3, 4, 5, 6.
The sequence can have 1 to 6 steps.
E-STOP RESET sequence can use same button several times.
For example: step 1 = 3 and step 4 = 3.
Summary of Contents for eXLhoist
Page 12: ...12 EIO0000001505 12 2014...
Page 34: ...Wireless Remote Control System 34 EIO0000001505 12 2014...
Page 52: ...52 EIO0000001505 12 2014...
Page 146: ...Using The Wireless Remote Control System 146 EIO0000001505 12 2014...
Page 200: ...eXLhoist Configuration Software 200 EIO0000001505 12 2014...
Page 213: ...EIO0000001505 12 2014 213 Harmony eXLhoist EIO0000001505 04 2014 Appendices...
Page 214: ...214 EIO0000001505 12 2014...