- 12 -
V6-04-05
Assembly instructions Veranda sunblind VZ520
E. Electrical connections:
E1. Flow chart for a single-pole switch:
There are 4 wires from the motor. Yellow-green (earth), blue (neutral), brown and black (raise and
lower)
From the fuse box, there are 3 wires. Yellow-green (earth), blue (neutral), and phase. Connect the wires
as shown in the diagram. The phase wire from the fuse box should be connected to terminal L. If neces-
sary, reverse the brown and black leads from the motor in the switch so that the arrows on the switch
correspond to rolling up and unrolling the sun blind.
The 2 earth wires are connected using separate clamps. Ditto for the 2 neutral wires.
yellow / green
brown / black
brown / black
red
blue