18 GB
• All local regulations including those referring to national and European standards must be observed when installing the appliance.
• Ensure there is sufficient ventilation / air supply in the room from which your stove gets the combustion air.
This is the room where the stove is installed if you do not use a wall or stove-base air-supply system.
• The stove is not suitable for a shared flue system.
• Ensure adequate access for cleaning the appliance, the flue gas connection and the chimney.
• When installing the stove, take into account the minimum distances from the wall so as to avoid any fire risk.
The minimum distances are shown in the figure below. (sizes in mm)
• The distances below apply to non-inflammable walls. Inflammable walls (e.g. wood) require different distances. Ask you supplier for advice.
Specifications Pharos Interior
• Nominal power of the stove is 9 kWatts.
• Flue gas mass flow = 26.7g/s
• Appliance weight = 100 kg
• Minimum chimney draught = 8,0 Pa
• Flue gas temperature directly over the stove = 387 °C
general InstruCtIons and regulatIons
Summary of Contents for PHAROS INTERIOR
Page 2: ......