NetWave DirectView Broadcast Console Operations & Technical Manual
Revision A
1 - Introduction
Harris Broadcast
1-9
PR&E
The Link connector outputs four stereo program buses, stereo cue bus, the two-channel Telco record output,
up to six dual mix-minus signals, and one stereo source from each channel as VistaMax network source
signals. The Link can also input a source signal from the VistaMax network to each fader channel and the
two External Monitor inputs.
Specifications
Harris Broadcast reserves the right to change specifications without notice or obligation.
General
Measured on a fully populated NetWave-24 with 100k Ω loads on the analog outputs.
0 dBu=0.775 volts RMS, regardless of circuit impedance (0 dBm into 600 Ω). Noise measured using a 20
kHz bandwidth. Add 1.7 dB for a 30 kHz bandwidth.
Total Harmonic Distortion (THD+N) measured with swept signal, at +18 dBu, with a 20 kHz low pass filter.
FSD (Full Scale Digital) = 0 dBFS (digital output),+24 dBu (analog output)
Dimensions
All NetWave console mainframes are 3" [76] maximum height above the countertop, except for the console
display, which is 6" [152] high. The front-to-back depth of all mainframe sizes is 21" [533].
NetWave-8 is 20" [508] wide; NetWave-16 is 32.4" [823] wide; and NetWave-24 is 45.2" [1148] wide.
PRE99-1206 in-line supply for NetWave-8 and -16: 2" [51] x 3.8" [97] x 9.5" [241]
PRE99-1205 rackmount supply for NetWave-24 is 2 RU: 3.5" [89] x 19" [483] x 10" [254]
All dimensions - Height x Width x Depth, except as noted.
Power Supplies
Supply included with console: PRE99-1206 (NetWave-8 and NetWave-16) or PRE99-1205 (NetWave-24).
Optional Power Coupler (PRE90-1995) available for adding a matching redundant supply for on-air consoles
AC input voltage & frequency: 90-240 VAC, 50/60 Hz
AC input: detachable IEC power cord
DC output: a keyed, latching connector on a captive cable on the PRE99-1206 supply or a detachable cable
(PRE90-1858-1) on the PRE99-1205 supply
Rackmount or in-line power supply: grounded through the AC input cord ground pin
Console Power Requirements
Measured at 120 VAC/60 Hz
NetWave-8: 54 watts; NetWave-16: 99 watts; and NetWave-24: 141 watts
Required Supply Voltage & Current
NetWave-8: +48 VDC @ 1.2 amps; NetWave-16: +48 VDC @ 2 amps; NetWave-24: +48 VDC @ 3 amps