Section 5
♦
Global Setup Menu Functions
78
CMN-41 Series Installation and Operation Handbook
Copyright © 2009, Harris Corporation
Gamut Setup Menu Selection Options
The Gamut Setup menu is used to change a gamut’s color plots, Data Error Persistence,
Intensity, Contrast, and Persistence. The Gamut Setup selection options are described
below.
•
Single Color, RGB, Composite (Color Plot)
: These selection options are used to
set the color for plotting RGB pixels. The pixels can be one single color or RGB
(red, green, or blue). Multiple colors help to indicate which color of the RGB signal
moves beyond the inner and outer parameters of the gamut graticule. The default
selection is RGB.
•
Data Error Persistence
: This selection option is used to determine how long a
point of data beyond the inner and outer parameters of the gamut graticule. The
range of persistence is 0% to Infinite. The default selection is 0%.
•
Intensity
: This selection option is used to raise or lower the brightness of the
displayed gamut. The range of intensity is 0% to 100%. The default selection is
86%.
•
Contrast
: This selection option is used to adjust the overall difference between the
lightest and darkest colors of the gamut. The range of contrast is 0% to 100%. The
default selection is 55%.
•
Persistence
: This selection option is used to determine how long a data point
(pixel) in the Gamut remains on the display. The range of Persistence is 0% to
Infinite. The default selection is 0%.
Picture Setup Menu Selection Options
The Picture Setup selection options are described below. The default selection is
Anamorphic.
•
Markers
: There are several markers available to be indicated in a picture.
•
Center
is equal to 50% of the picture height and 50% of the picture width.
•
Safe Title
is equal to 80% of the picture height and 80% of the picture width.
•
Safe Action
is equal to 90% of the picture height and 90% of the picture width.
•
Clean Aperture
shows the limits for the active pixel area. Brackets appear on
the picture or a box surrounds the picture to show these limits. The center marker
identifies the location of the center of the picture.
•
Custom (Corners) and Custom (Box)
allows the setup of customized markers
for a picture display.
•
Custom Position
is used in conjunction with the Custom Corners and Custom
Box selections. It allows the adjustment of the custom corner or box size.
•
Custom Length
is used in conjunction with the Custom Corners selection
option. It allows the adjustment of the corner lengths.
•
Anamorphic
: This selection option is used to correct the anamorphic display.
Setting the menu selection to ON changes the actual source aspect ratio to an aspect