26HFS6801
+
Installation and Operation Manual
Chapter 3: Operation
Changing Parameter Settings
Note
For best results, use the available 6800
+
software control options
(serial/local or Ethernet/remote) to aid in viewing, setting, and
confirming parameter values.
Follow these steps to change the HFS6801
+
parameter settings:
1. Rotate the mode select rotary switch (hex switch) to “0.”
2. Once the hex switch is set to “0,” toggle the navigation switch up or
down to select a bank.
View the two control LEDs next to the navigation toggle switch to
see which bank is currently selected.
to view the various banks, hex switch
positions, and corresponding parameter options and values.
3. Rotate the hex switch to the parameter number (1 to 9) or letter
(A to F) of the option you want to set.
4. Toggle the navigation switch to select and set the value of the
chosen parameter.
Table 3-2. Selected Bank as Indicated by Control LEDs
Bank Select LED 1
(first top LED)
Bank Select LED 2
(second top LED)
Bank Select LED 3
(third top LED)
Bank Number
Off
Off
Off
0
On
Off
Off
1
Off
On
Off
2
On
On
Off
3
Off
Off
On
4
On
Off
On
5
Off
On
On
6
On
On
On
7
Summary of Contents for HFS6801+
Page 1: ......
Page 2: ......
Page 8: ...vi HFS6801 Installation and Operation Manual Contents...
Page 22: ...8 HFS6801 Installation and Operation Manual Chapter 1 Introduction...
Page 58: ...44 HFS6801 Installation and Operation Manual Chapter 4 Specifications...
Page 70: ...56 HFS6801 Installation and Operation Manual Index...
Page 71: ......