NEXIO AMP
Hardware Installation and User Guide
27
©2011 Harris Corporation. All rights reserved.
Remote GPI
Control
The following table describes the GPI control specifications for the
NEXIO AMP.
Remote
Serial
Interface
The following list describes the remote serial interface specifications for NEXIO
AMP:
RS-422 ports for control of up to eight channels; one port can be allocated for
a VTR
RJ-12 connector
Harris ADC VDCP pinout (see
Controls
The following table describes NEXIO AMP control specifications.
Physical
The following table describes NEXIO AMP size specifications.
Table 1-12
GPI Control Specifications for NEXIO AMP
Inputs
32 inputs (two 26-pin MDR connectors)
Outputs
16 outputs (two 26-pin MDR connectors)
Table 1-13
Control Specifications
Input/Output
Ethernet, TCP/IP via socket or UDP
RS-422
GPI
Protocols
NEXIO Native Protocol
VDCP
Sony 9-Pin
Table 1-14
Size Specifications
Height
5.25 in. (13.4 cm); 3RU
Width
19 in. (48.3 cm)
Length
26 in. (71.4 cm) from the rack ears to the rear panel
Weight
47 lbs. (21.3 kg)