Cable clearance —
Provide at least 2 inches of clearance in the rear of the
rack for cabling.
Ensure that the rack is anchored to the floor so that it cannot tip over when
NEXIO AMP is extended out of the rack.
To rack mount NEXIO AMP
1
Remove the slides from the rails.
2
Attach a slide to each side of the NEXIO AMP chassis. The release latch on the slide
faces the rear of the frame.
3
Attach an extension to the back of each rail to match the depth of your rack.
4
Attach the rails to the rack posts.
5
Pull the inner rail out until it locks.
6
Slide the NEXIO AMP into the rail until it stops; press the release latch on each slide
and continue to slide the NEXIO AMP into the rail until it locks.
7
Press the release button on the outside of the rail and slide the NEXIO AMP all the
way into the rack.
Figure 2-1
Rack Mounting
front rack
posts
rear rack
posts
extension
slide
release latch
release button
slide