QSEE6800
+
H Installation and Operation Manual
29
Chapter 3: Card-Edge and Parameter Operation
QSEE6800
+
H Input Parameters
In addition to remote controls for the QSEE6800
+
H module, there is a
separate control panel for each input to the module. These controls are
outlined in
. For more information on the QSEE6800
+
H
Input control window, see
Table 3-3.
Parameter Options—QSEE6800
+
H Inputs—Remote Control Only
Parameter Name
1
Function
Options
UMD ID
Shows the name of the module as
it will appear on other
QSEE6800
+
H displays
String
Thumbnail Resolution
Determines the size of the
thumbnail that will be output on
this Control window
• Disable
•
Low
• Medium
• High
Rate
Determines the refresh rate of the
thumbnail on this Control window
• 2 frames/sec
•
1 frame/sec
• 1 frame/2 sec
• 1 frame/3 sec
• 1 frame/4 sec
• 1 frame/5 sec
• 1 frame/6 sec
• 1 frame/7 sec
• 1 frame/8 sec
• 1 frame/9 sec
• 1 frame/10 sec
(Line Sample Setting) Enable
Activates or deactivates line
sampling
• Off
• On
Line Number
Selects the line for line sampling
Range:
• 1 to 1125 (for 1080i/1080p line
standards)
• 1 to 750 (for 720p line standards)
• 1 to 625 (for 625 line standard)
• 1 to 525 (for 525-line standard)
(
50
)
Status [RO]
Indicates whether there is a signal
or not
• Present
• Absent