5.2.1 

Adding a Subscriber 

To add a new 

Subscription

 endpoint, click on the small icon   on the left side of the report  

and then click on 

New Subscription

.  

A dialog will appear where a subscription can be configured.  

If no subscriber was configured before, a new one can be configured by selecting 

New 

Subscriber …

 in the 

Subscriber

 box. 

A dialog will appear where you can add a new subscriber endpoint to publish the gathered 
information from the injection molding machine. The supported types of endpoints are 
AZURE, HTTP, HTTPS, JDBC, MQTT, MQTTS, TCP and UDP.  

 

 

 

Leave the Client ID blank to use an autogenerated 
ID. Otherwise, make sure to use a unique ID. 

 

 

 

 

Once configured, the Subscription endpoints can be activated and deactivated with a click 
on 

 or deleted by clicking  . 

5.2.2 

Deleting a Subscriber 

You can delete a subscriber by moving your mouse over on a subscriber and clicking the 

Delete

 button. 

Summary of Contents for OPC-UA

Page 1: ...HARTING OPC UA Gateway for MICA User Manual...

Page 2: ...ts reserved including those of the translation No part of this manual may be reproduced in any form print photocopy microfilm or any other process processed duplicated or distributed by means of elect...

Page 3: ...ontainer Operations 6 3 1 Network Settings 6 4 About OPC UA 7 5 Using the OPC UA Gateway 8 5 1 Devices 8 5 2 Reports 10 5 2 1 Adding a Subscriber 11 5 2 2 Deleting a Subscriber 11 6 Executor 12 6 1 Er...

Page 4: ...n Without a license key the container will be stopped automatically after 6 hours New Features Improved user and rest based web interface Tree walk mechanism for the device definition A user can now b...

Page 5: ...elect the installation archive 4 Click Execute to start the installation 5 The installer will display the readme file with information about the installation archive 6 Enter the name you want to insta...

Page 6: ...n On Mode Duplicate Duplicates the container on your MICA Export Exports the container to your PC or a network drive All configurations you set will be kept Merge Overwrites the reset point of the con...

Page 7: ...rk This multi layered approach accomplishes the original design specifications goals of 1 Functional equivalence all COM OPC Classic specifications are mapped to UA 2 Platform independence from an emb...

Page 8: ...tes that the OPC UA Gateway container is not yet licensed and running in demo mode In this mode the container will be stopped every 6 hours but can be restarted manually To obtain a license key click...

Page 9: ...ick on Clicking on the Field box to open a dialog that lets you create a field for the device new dialog If the OPC UA Gateway is connected to a device you can also click the magnifying glass to recei...

Page 10: ...and fill in the required information in the configuration window A unique Name for the report The Duration of the report in milliseconds i e how long the report should run The Repeat Period of the re...

Page 11: ...in the Subscriber box A dialog will appear where you can add a new subscriber endpoint to publish the gathered information from the injection molding machine The supported types of endpoints are AZUR...

Page 12: ...can be a numeric value or a string This property will only be visible if no field was selected as the Identifier Run the Executor by clicking the button 6 1 Error messages When executing an OPC UA que...

Page 13: ...ormation To see the log entries click the Expand Log button The following operations can be done in the Log part Select the types of messages to be displayed Reload log information Export the log info...

Page 14: ...AME rest opcuagateway executor tcp 127 0 0 1 3A4840 rfr310 DeviceName 4 string You will see something like the following In the address contains the REST path followed by the same information you must...

Reviews: