 HARTING 

MICA OPC-UA  Gateway 

 User Manual

 

 

peraMIC GmbH & Co. KG 

Using the OPC UA Gateway  

To open the Gateway user interface, click its container tile after the container has started 
and the tile has changed from gray to yellow.  

 

 

The 

 button with an exclamation mark indicates that the OPC UA Gateway 

container is not yet licensed and running in demo mode. In this mode, the container will be 
stopped every 6 hours, but can be restarted manually.  

To obtain a license key, click on 

Activate

 and follow the steps described in the popup 

window. 

5.1

 Devices 

In the section Devices you can create, edit and import OPC UA devices from which you 
want to collect data.  

 

To add a new device, click the add button and configure the device in the pop up window. 

Summary of Contents for OPC-UA

Page 1: ...HARTING OPC UA Gateway for MICA User Manual...

Page 2: ...ts reserved including those of the translation No part of this manual may be reproduced in any form print photocopy microfilm or any other process processed duplicated or distributed by means of elect...

Page 3: ...ontainer Operations 6 3 1 Network Settings 6 4 About OPC UA 7 5 Using the OPC UA Gateway 8 5 1 Devices 8 5 2 Reports 10 5 2 1 Adding a Subscriber 11 5 2 2 Deleting a Subscriber 11 6 Executor 12 6 1 Er...

Page 4: ...n Without a license key the container will be stopped automatically after 6 hours New Features Improved user and rest based web interface Tree walk mechanism for the device definition A user can now b...

Page 5: ...elect the installation archive 4 Click Execute to start the installation 5 The installer will display the readme file with information about the installation archive 6 Enter the name you want to insta...

Page 6: ...n On Mode Duplicate Duplicates the container on your MICA Export Exports the container to your PC or a network drive All configurations you set will be kept Merge Overwrites the reset point of the con...

Page 7: ...rk This multi layered approach accomplishes the original design specifications goals of 1 Functional equivalence all COM OPC Classic specifications are mapped to UA 2 Platform independence from an emb...

Page 8: ...tes that the OPC UA Gateway container is not yet licensed and running in demo mode In this mode the container will be stopped every 6 hours but can be restarted manually To obtain a license key click...

Page 9: ...ick on Clicking on the Field box to open a dialog that lets you create a field for the device new dialog If the OPC UA Gateway is connected to a device you can also click the magnifying glass to recei...

Page 10: ...and fill in the required information in the configuration window A unique Name for the report The Duration of the report in milliseconds i e how long the report should run The Repeat Period of the re...

Page 11: ...in the Subscriber box A dialog will appear where you can add a new subscriber endpoint to publish the gathered information from the injection molding machine The supported types of endpoints are AZUR...

Page 12: ...can be a numeric value or a string This property will only be visible if no field was selected as the Identifier Run the Executor by clicking the button 6 1 Error messages When executing an OPC UA que...

Page 13: ...ormation To see the log entries click the Expand Log button The following operations can be done in the Log part Select the types of messages to be displayed Reload log information Export the log info...

Page 14: ...AME rest opcuagateway executor tcp 127 0 0 1 3A4840 rfr310 DeviceName 4 string You will see something like the following In the address contains the REST path followed by the same information you must...

Reviews: