EN
Instructions for installation and use
p. 7/12
5. Connection diagram
Observe the following points when connecting the power to the sauna control unit:
Ɣ
Work on the sauna control unit may only be performed when the power has
been disconnected.
Ɣ
Observe the assembly instructions for the respective sauna control unit
black – ST1 ..................
brown – L1 ...................
grey – N .......................
red – S (remote start) .....
red – B (remote start) .....
With
4
and
5
:
Ɣ
Polarity not relevant
Ɣ
When using with door monitoring, observe the instructions for door
monitoring
1
2
3
45
5.1. Connection to Pro series (Pro B2/3, Pro C2/3, Pro D)
1
2
3
4
5