Installation instructions, only for experts
p. 10/28
4. Installation and connection
Take the following points into account when positioning and connecting the
sauna heater:
If there is sufficient ventilation, the Qube sauna heater can also be situ
-
ated in a free-standing position. In this case, fit the temperature sensor
to the cabin roof above the centre of the heater.
● The electrical connection may only be performed by a qualified electrician or
similarly qualified person.
●
A fully disconnecting all-pole isolating device compliant with overvoltage
category III must be fitted on site.
●
The Qube sauna heater is a free-standing heater. It does not need to be at-
tached to the floor or sauna wall.
● Do not place the sauna heater on a floor made from an easily flammable
material such as wood or plastic. Suitable flooring includes ceramic tiles, for
example.
●
The 3-shell technology means that no additional protection against contact is
required because the surface temperatures of the heater are low.
4.1. Installation location and sensor position
Position the heater centrally in front of the air intake opening in the cabin wall.
Comply with the safety distances to the cabin wall specified in
Fig. 1
and
Fig. 2
.
Install the temperature sensor with excess temperature cut-out to the cabin wall
above the centre of the sauna heater. Maintain a distance of 15 cm to the sauna
cabin roof.
WARNING!
Danger of electric shock
●
The sauna heater may only be installed and connected when the
power supply is disconnected.
Summary of Contents for sentiotec Qube
Page 28: ...NOTIZEN APPUNTI NOTES NOTE NOTITIES ...
Page 56: ...NOTIZEN APPUNTI NOTES NOTE NOTITIES ...
Page 84: ...NOTIZEN APPUNTI NOTES NOTE NOTITIES ...
Page 112: ...NOTIZEN APPUNTI NOTES NOTE NOTITIES ...
Page 140: ...NOTIZEN APPUNTI NOTES NOTE NOTITIES ...
Page 168: ...NOTIZEN APPUNTI NOTES NOTE NOTITIES ANTECKNINGAR ...
Page 196: ...NOTIZEN APPUNTI NOTES NOTE NOTITIES ...
Page 224: ...NOTIZEN APPUNTI NOTES NOTE NOTITIES BELEŽKE ...