background image

                               HASEL ÜTÜ SAN.TİC. ve LTD.ŞTİ.                          4 

 

 

 

MEANING OF SAFETY SYMBOL 

 
 

 

 

 
 
                                            
                         
 

 
  

            Read the manual                          Repairs should be made  

             before use                              by Qualified Person only                                                                               

  
                
 
                                            

 

 

               
                                                                                   
                
 
                     Electricity                                                High Temperature 
                           
                                                                                    
                       
 
                Main Grounding                                            Internal Grounding 

            

 

 

 

 
 

     
                                                    

 

Stop the machine 

Before maintenance 

 
 

 

Summary of Contents for HSL-GP-03K

Page 1: ...WIDE IRONING TABLE WITH VACUUM HSL GP 03S HSL GP 03K HSL GP 03KI ...

Page 2: ...Meaning of Safety Symbols 4 Description And Intended Use 5 Technical Specifications 5 Technique Drafting 6 Storage 7 Transport And Handling 7 General Safety Precautions 8 9 Mounting Instructions 10 Using Instructions 10 11 Maintenance Instructions 11 Trouble Fixing 12 ...

Page 3: ...I This information intended to help operator Any problems questions about this manual should be informed to our head office to obtain necessary information by e mail or telephone MANUFACTURER HASEL ÜTÜ SAN ve TİC LTD ŞTİ FACTORY İkitelli Organize San Böl Demirciler San Sit B2 Blok No 71 72 K çekmece İstanbul TURKEY Tel 90 212 671 32 43 90 212 671 41 02 Fax 90 212 671 32 44 WEB http www haselutu co...

Page 4: ...TİC ve LTD ŞTİ 4 MEANING OF SAFETY SYMBOL Read the manual Repairs should be made before use by Qualified Person only Electricity High Temperature Main Grounding Internal Grounding Stop the machine Before maintenance ...

Page 5: ...Models with arm makes ironing easier and better for arms of clothes Using machine with the exception of above determined condition eliminates manufacturer s responsible for damage and injury TECHNICAL SPECIFICATIONS TYPE HSL GP 03S HSL GP 03K HSL GP 03KI Voltage 220 V or 380V 220 V or 380V 220 V or 380V Frequency 50 Hz 50 Hz 50 Hz Total Power 3 55kW 3 55 kW 4 kW Vacuum Motor 0 55 kW 0 55 kW 0 55 k...

Page 6: ...İ 6 TECHNIQUE DRAFTING HSL GP 03KI PART NAME NO Power Plug 1 Main Switch 2 Thermostat 3 Thermostat Signal Lamp 4 Changing Rod For Vacuuming 5 Vacuum Pedal 6 Feet 7 Table Frame 8 Swivel Arm 9 Arm Heating Switch 10 Seat For Iron 11 ...

Page 7: ...care during handling of the machine Comply with the precautions necessary and marked on the cards on the packing and follow chapters carefully Unpacking and Handling Machine is packed in two ways Wrapped by thick nylon or Placed in a wooden cage If the machine is wrapped by a nylon cover by putting on transpalette or lifting up carry it to where you want to place If the machine placed in a wooden ...

Page 8: ...All warning labels which are placed on machine meanings were pointed above Please pay attention Do not use machine in the vicinity of combustible fluids or gases Do not let people other than those who are sufficiently trained to operate the machine This machine is in accordance with the relevant safety regulations Repairs must be performed only by an electrical specialist otherwise accidents can r...

Page 9: ...ician shift the cable User should not leave the machine alone while it is working After ironing place hand iron on the hand iron mat Do not work machine upper 100 C long time Table cover can be burned Do not displace swivel arm Before start maintenance turn of main switch Do not touch hot places if the covers are removed at the maintenance Electric and steam output must be off Do not pull out the ...

Page 10: ...nstruction Your machine can get trouble by low or high voltage and this situation is not in guarantee You can obviate the low or high voltage by using an automatic voltage regulator USING INSTRUCTIONS Usage of Counter Tables 1 Open the main switch 2 2 Turn the heater thermostat 3 Adjust working temperature by using the table heater thermostat and don t exceed 100 o C Do not forget if machine works...

Page 11: ...ion for vacuuming 3 For vacuuming just pres the vacuum pedal 6 4 For type of HSL GP 03KI open the arm heating switch 10 if you want to heat the arm MAINTENANCE INSTRUCTIONS Before repairing operation turn the main switch 2 absolutely off If you take away the protective parts during the maintenance you have to careful not to touch hot places Certainly you must turn off the electricity and steam out...

Page 12: ...NG VERY HOT Thermostat 3 may be broken Call the service Thermostat adjustment may be high Control thermostat adjustment MOTOR DOES NOT MAKE VACUUMING Pedal switch may be broken Main switch 2 may be broken Call the service Motor may be turning wrong direction Call electrician to check electricity connection to wall fuse MOTOR WORKS LOUDLY Motor fan maybe broken Call the service Motor may be turning...