DESCRIPTION AND INTENDED USE 

 
 

 
 

Product Name: Wide Ironing Table With Vacuum 
               
              Model No: 

 

HSL-GP-03S

: Wide Ironing Table With Vacuum 

 

HSL-GP-03K

: Wide Ironing Table With Vacuum and 

Arm 

 

HSL-GP-03KI

:  Wide  Ironing  Table  With  Vacuum 

and Arm Heating. 

 
HSL-GP-03S, 

HSL-GP-03K, 

HSL-GP-03KI 

are 

wide 

type                   

ironing tables. Used for ironing all types of clothes. Models with arm, 
makes ironing easier and better for arms of clothes.  
 

Using  machine  with  the  exception  of  above  determined  condition 
eliminates manufacturer’ s responsible for damage and injury. 

 

 

TECHNICAL SPECIFICATIONS 

 

 

 

TYPE 

HSL-GP-03S 

HSL-GP-03K 

HSL-GP-03KI 

Voltage 

220 V or 380V  220 V or 380V 

220 V or 380V 

Frequency 

50 Hz 

50 Hz 

50 Hz 

Total Power 

3.55kW 

3.55 kW 

4 kW 

Vacuum Motor 

0,55 kW 

0,55 kW 

0,55 kW 

Table Heating 
El. 

2*1,5 kW 

2*1,5 kW 

2*1,5 kW 

Arm Heating El. 

------ 

----- 

0,5 kW  

IP Code 

Ip 54 

Ip 54 

Ip 54 

Dimensions 

140*80*91 cm 

140*90*93 cm 

140*90*93 cm 

Weight 

56kg 

61 kg 

61  kg 

Summary of Contents for HSL-GP-03K

Page 1: ...WIDE IRONING TABLE WITH VACUUM HSL GP 03S HSL GP 03K HSL GP 03KI ...

Page 2: ...Meaning of Safety Symbols 4 Description And Intended Use 5 Technical Specifications 5 Technique Drafting 6 Storage 7 Transport And Handling 7 General Safety Precautions 8 9 Mounting Instructions 10 Using Instructions 10 11 Maintenance Instructions 11 Trouble Fixing 12 ...

Page 3: ...I This information intended to help operator Any problems questions about this manual should be informed to our head office to obtain necessary information by e mail or telephone MANUFACTURER HASEL ÜTÜ SAN ve TİC LTD ŞTİ FACTORY İkitelli Organize San Böl Demirciler San Sit B2 Blok No 71 72 K çekmece İstanbul TURKEY Tel 90 212 671 32 43 90 212 671 41 02 Fax 90 212 671 32 44 WEB http www haselutu co...

Page 4: ...TİC ve LTD ŞTİ 4 MEANING OF SAFETY SYMBOL Read the manual Repairs should be made before use by Qualified Person only Electricity High Temperature Main Grounding Internal Grounding Stop the machine Before maintenance ...

Page 5: ...Models with arm makes ironing easier and better for arms of clothes Using machine with the exception of above determined condition eliminates manufacturer s responsible for damage and injury TECHNICAL SPECIFICATIONS TYPE HSL GP 03S HSL GP 03K HSL GP 03KI Voltage 220 V or 380V 220 V or 380V 220 V or 380V Frequency 50 Hz 50 Hz 50 Hz Total Power 3 55kW 3 55 kW 4 kW Vacuum Motor 0 55 kW 0 55 kW 0 55 k...

Page 6: ...İ 6 TECHNIQUE DRAFTING HSL GP 03KI PART NAME NO Power Plug 1 Main Switch 2 Thermostat 3 Thermostat Signal Lamp 4 Changing Rod For Vacuuming 5 Vacuum Pedal 6 Feet 7 Table Frame 8 Swivel Arm 9 Arm Heating Switch 10 Seat For Iron 11 ...

Page 7: ...care during handling of the machine Comply with the precautions necessary and marked on the cards on the packing and follow chapters carefully Unpacking and Handling Machine is packed in two ways Wrapped by thick nylon or Placed in a wooden cage If the machine is wrapped by a nylon cover by putting on transpalette or lifting up carry it to where you want to place If the machine placed in a wooden ...

Page 8: ...All warning labels which are placed on machine meanings were pointed above Please pay attention Do not use machine in the vicinity of combustible fluids or gases Do not let people other than those who are sufficiently trained to operate the machine This machine is in accordance with the relevant safety regulations Repairs must be performed only by an electrical specialist otherwise accidents can r...

Page 9: ...ician shift the cable User should not leave the machine alone while it is working After ironing place hand iron on the hand iron mat Do not work machine upper 100 C long time Table cover can be burned Do not displace swivel arm Before start maintenance turn of main switch Do not touch hot places if the covers are removed at the maintenance Electric and steam output must be off Do not pull out the ...

Page 10: ...nstruction Your machine can get trouble by low or high voltage and this situation is not in guarantee You can obviate the low or high voltage by using an automatic voltage regulator USING INSTRUCTIONS Usage of Counter Tables 1 Open the main switch 2 2 Turn the heater thermostat 3 Adjust working temperature by using the table heater thermostat and don t exceed 100 o C Do not forget if machine works...

Page 11: ...ion for vacuuming 3 For vacuuming just pres the vacuum pedal 6 4 For type of HSL GP 03KI open the arm heating switch 10 if you want to heat the arm MAINTENANCE INSTRUCTIONS Before repairing operation turn the main switch 2 absolutely off If you take away the protective parts during the maintenance you have to careful not to touch hot places Certainly you must turn off the electricity and steam out...

Page 12: ...NG VERY HOT Thermostat 3 may be broken Call the service Thermostat adjustment may be high Control thermostat adjustment MOTOR DOES NOT MAKE VACUUMING Pedal switch may be broken Main switch 2 may be broken Call the service Motor may be turning wrong direction Call electrician to check electricity connection to wall fuse MOTOR WORKS LOUDLY Motor fan maybe broken Call the service Motor may be turning...

Reviews: