background image

 

HASEMAN ELECTRIC   

 

 

 

RS-10PM2 

USER MANUAL 

 

   Haseman 

RS-10PM2

  is  a  10-channel,  DIN  Rail, 

Relay  module  with  true  RMS  energy  meter, 
produced  by  using  Z-Wave  Plus,  the  latest  version 
of Z-Wave.  
   RS-10PM2  is  optically  isolated  and  protected 
against  voltage  surges,  caused  by  switching  of 
inductive and capacitive loads as power contactors, 
motors, EM valves and switching power supplies.  
   Zero-cross  switching  technology  ensures  high 
reliability and long relay life. 

 

  WHAT IS Z-WAVE? 

 

Z-Wave  is  an  international  standard  protocol  for 
wireless  communication  in  smart  homes  and 
building  systems.  It  enables  smart  home  products 
to  talk  to  each  other  and  creates  the  backbone  of 
your smart home. Z-Wave based system allows you 
to  use  your  smartphone  or  tablet  to  create  one-
touch  scenes  that  help  with  your  daily  activities: 
saving  energy,  keeping  your  home  secure  and 
being more comfortable. 
Z-Wave  technology  is  simple:  each  transmitted 
message  is  reconfirmed  (2-way  communication) 
and  every  mains  powered  device  can  act  as  a 
repeater  for  other  devices  (mesh  network).  The 
more  Z-Wave  products  you  have  in  your  smart 
home, the stronger your smart home network is.  
Z-Wave technology  is the  leading solution  in smart 
home automation. There is a wide range of Z-Wave 
devices  that  are  compatible,  independently  of  the 
manufacturer  which  gives  the  system  an  ability  to 
evolve and expand over time. 

 

  SAFETY INFORMATION 

 
Read  this  manual  before  attempting  to  install  the 
device! 

Failure 

to 

observe 

recommendations 

included in this manual may be dangerous or cause 
a violation of the law.  

 

The  manufacturer  will  not  be  held  responsible  for 
any loss or damage resulting from not following the 
instructions of operating manual. 
 

DANGER OF ELECTROCUTION!

  

 

All works on the device may be performed 
only by a qualified and licensed electrician. 
Observe national regulations.  

  
The  device  is  designed  to  operate  in  electrical 
home  installation.  Faulty  connection  or  use  may 
result in fire or electric shock.  

 

Even  when  the  device  is  turned  off,  voltage  may 
be present at its terminals.  

 

Any  maintenance  introducing  changes  into  the 
configuration  of  connections  or  the  load  must  be 
always performed with disabled fuse.

 

 
  CONNECTION DIAGRAMS 
 

When connecting the module, observe the 
proper Neutral (

N

) and Line (

L

) terminals. 

 

 

 

Only  the  provided  current  clamp  can  be 

connected to Input terminals 

CT1

 and 

CT2

 

Each relay channel has its own Input (

In

and Output (

O

), which allows controlling of 

devices, supplied by different voltages (12, 
24, 48VDC / VAC, 110-240 VAC, etc.) 

 

   INSTALLATION 
 

 

Mount the module on standard DIN Rail. 

 

 

Connect the controlled lines. Depending on the 

load supply voltage, use one of the following 
connection diagrams: 

 
 

   For 230 VAC Loads: 
 

 
 

      For low voltage AC/DC Loads: 
 

 

 

During operation, each channel 
status is indicated by panel 
indication LED.

 

 

  

 

 

 

Connect the local  control  lines  S1 to S10 (if  local 

control  is  used).  Depending  on  the  BUTTON  TYPE 
Parameter  (separate  for  each  Channel),  Push 
Buttons or Toggle Switches can be connected:  

 

 
 

Only Voltage Free

 contacts must be 

connected between terminal 

Com

 and 

terminals 

S1

 to 

S10

 
 

 

Connect the Current clamp to inputs CT1-CT2 and 

fix it on the monitored power line. 

 
 

 
 
 
 

 

Connect the supply to  Neutral  and Line terminals

and wait for 30 second until the module initialization 
process is completed.

 

 
 

Summary of Contents for RS-10PM2

Page 1: ...olation of the law The manufacturer will not be held responsible for any loss or damage resulting from not following the instructions of operating manual DANGER OF ELECTROCUTION All works on the device may be performed only by a qualified and licensed electrician Observe national regulations The device is designed to operate in electrical home installation Faulty connection or use may result in fi...

Page 2: ...the module to power supply Set the Z Wave controller into INCLUSION mode adding new device to the Network Triple click the Z Button on the front panel Be patient until the inclusion process is completely finished Multichannel devices usually need a bit more time for complete configuration After the inclusion it will appear a separate instance Node for each relay channel as well as additional nodes...

Page 3: ...f following the state of the corresponding Output 1 to Output 10 behavior depends on the value of the configuration parameter for the Button Input type parameter 65 to 73 individual for each channel Association ensures direct transfer of control commands between devices i e it is performed without participation of the main controller and requires associated device to be in a direct range Sample co...

Page 4: ...ear such as parts that require periodic replacement during the normal operation of the system Splits cracks scratches dents scratched or discolored surfaces and parts breakage of plastic parts and any other cosmetic damage Damages resulting from use of the system other than that provided including but not limited to the failure to follow instructions contained in the operating manual Damages cause...

Reviews: