Hastings
Operations Manual
Page 17
4.
My stove isn’t burning and the #2 and #3 Feed Lights are blinking simultaneously.
These 2
LED lights diagnose the High Limit Switch and will indicate the stove reached an Over Temp
situation.
a.
Check to see if the High Limit switch needs to be reset. If the High limit
switch needs to be reset, do not use the stove until you find out why the High
Limit tripped.
b.
The room air fan could be defective or the fan may need cleaning.
c.
The high limit switch also may be defective. It is best to call your dealer for
support when trying to troubleshoot the High Limit Switch. Do not use your
stove if the High Limit switch frequently trips.
5.
I lit the stove and the # 2 Feed Light immediately started blinking and smoke spills out of
the stove.
How do I get the stove to quit smoking?
Cause:
The stove did not establish a vacuum
and shut down. With the fuel in the pot
burning, the smoke finds the path of least resistance and leaks out into the house.
(See Installations Manual. Minimum vertical height needed to establish some
natural draft and prevent smoke spillage)
Solution:
Pull the Slide-Out Bottom out and drop the fuel into the ash pan. This will
minimize the amount of smoke that can spill into the room.
6.
I turned the stove on with the On/Off switch and nothing happens.
First check to see if the
stove is plugged in and the receptacle has power to it.
Solution:
Check the fuse on the back of the control board. Replace with a 250 Volt, 5 Amp
fuse. Part Number 80P20057-R
7.
Why is my glass dirty?
Normal operation of your St. Croix stove will produce a white/tan
build-up on the glass that wipes off with a dry paper towel. However, extended burning on the
low setting only, will produce a darker tan color. These types of build-up on the glass are normal.
A heavy black build-up on the glass could indicate a problem.
Solution:
Adjust the combustion air setting to the proper setting. If this doesn’t seem to
help, make sure the clean out cover plates are installed in the stove. It also could
be an indication that the stove is getting plugged and needs a good cleaning. Refer
to the section in the manual that covers the Daily, Periodic and Yearly
Maintenance of the stove.