User’s Manual of AL8010F
Heating or Cooling Controller (TC1-1412-1006)
1. Features
Within
adjustable
Aim Temperature Value, Temp. Difference Value, Compressor Delay
Time and calibration value; Higher and Lower temperature limit exceed which range will
trigger
alarms
.
It will change the room temperature by
turn on / off the load automatically
.
Auto memory
exist data if electric off, need not to configure it again once power back.
With 0.1°C precision and ±1.0°C accuracy;
The voltage of input electric for the load
need not
to same as the voltage of this controller
and it is also working if they are same.
The output relay for load max bear
30A current
under 220V, allow 6600W load.
2. Application
Suit to place where need constant temperature, like beer fermentation chamber / pool, brewing
hardware, boiler, fridge, freezer, Incubators, Aquariums, Hatchers, terrariums etc.
3. Package
Controller
1PCS
Fasteners
2PCS
Sensor
1PCS
Manual
1PCS
Waterproof Cover
1PCS
4. Specification
Input Power
220V AC ± 10% 50/60HZ; (12V/24/110V Option)
Maximum current
10A (Default) under 220V AC
Sensor
NTC, 25°C /10 KΩ, sensor cable 200cm
Protection Class
IP65 to front panel
Storage
-10°C ~ 60°C, RH<90%, without condensation
Meas. & Control:
-50°C ~ +120°C
Precision:
0.1°C
Accuracy:
± 1°C
Rated Power:
≤ 3W
5. Environmental Information
Package: The packages material is 100% recyclable; Just dispose it through
specialized recyclers.
Product: The electro components can be recycled or reused if it is disassembled
for specialized companies.
Disposal: Please do not burn or throw the controllers in domestic garbage, observe
the respectively law in your region concerning the environmental
responsible manner of dispose its devices.
6. Interface & Operation
6.1. Front Panel & Icon
Under normal status
When screen light, Press
and hold on
3s to turn off the display, attention it is turn
off controller not just dim the screen;
When screen dark, Press
and release, to
light on the screen.
Indicator / Character in Display
Indicator Meaning
On
Hide
Wink
Working status of load Load Working
Stop
Delay
Setting status
On Set
Non-setting
N/A
6.2. Dimensions & Installation
A.
Suggested amount dimension: 71.0*29.0*85.0mm (W*H*D)
B.
Detach the slide fasteners, put the controller into the hole, wiring follow diagram;
C.
Install the fasteners, and the waterproof cover.
D.
Please
avoid
installing in the below environments:
Relative humidity > 90%, have condensation
The places that temperature <-10°C or >60°C;
The places that have inflammables and explosives;
Strong vibration or struck
Exposed to the continuous water mist spraying;
Exposed to the dust;
Exposure to corrosive and pollution gas (for example: The gas, smoke or salt
fog that contain sulfur or ammonia;
Wireless electromagnetic interference or strong magnetic fields (near to
transmitting antenna or switch board room);