No.:GC-JS-21 Version: 01/00
Effective date
:
2020-03-30
21
The line on the process curve diagram will flash to indicate the running stage.
For the description of each stage, see Appendix III: Description of each stage
6.1.8 Explanation of each prompt message
No.
Prompt massages
Description
1
Please fill water
The water in the water storage tank is not enough to run the
program once, and water needs to be refilled
2
Empty waste
water tank
The waste water tank is full and needs to be emptied
3
Door open
Need to close the door before running the program
4
Bad water quality
The water in the water storage tank is unqualified: it needs to
be replaced with distilled or deionized water
5
Door locked
The door is locked to ensure that the door cannot be opened
during operation
6
Door locker open
The program ends and the door lock has been opened
6.1.7.2 The program runs after pressing the "Start" button, the interface is as follows
:
Total cycle time Current phase time
Current temperature
inside chamber
Current pressure
inside chamber
Current status(phase)
Program curve