background image

OPTIONS AND ACCESSORIES

12

Form No. FS2HACm-0815

English

Flip-Up Panel (FS2HAC-4PT only)

A flip-up panel option is available for installation in front of the

bottom two shelves on either side of the four-pan unit. The flip-

up panel provides better temperature control for units installed

in  locations  with  active  air  movement.  Use  the  following

procedure to install a flip-up panel (the procedure is the same

for either side).

NOTE: When referring to shelf positions in the unit, the bottom

shelf is shelf #1 and the top shelf is shelf #4.

1. Remove and save the pan support screws from the third

shelf pan supports. 

2. Align the left hinge bracket for the flip-up panel with the left

pan support screw hole.

3. Insert the left pan support screw through the hinge bracket,

through the pan support, and into the cabinet wall. Tighten

securely.

4. Align the right hinge bracket for the flip-up panel with the

right pan support screw hole.

Installing a Flip-Up Panel

5. Insert  the  right  pan  support  screw  through  the  hinge

bracket, through the pan support, and into the cabinet wall.

Tighten securely.

6. Remove one of the hinge screws from the panel hinge at

the top of the flip-up panel.

7. Insert the hinge screw remaining on the panel hinge into

one of the hinge brackets installed on the unit.

8. Align the other end of the panel hinge with the other hinge

bracket, and insert the removed hinge screw through the

hinge bracket and into the panel hinge. Tighten securely.

NOTE: Hatco  recommends  the  use  of  thread  locking

compound on the hinge screw before reassembly into

the panel hinge.

Flip-Up

Panel

Left Hinge

Bracket

Left Pan

Support

Screw

Third Shelf

Pan Support

Hinge

Screw

Flip-Up Panel Installed

Pans

Accessory aluminum sheet pans are available directly from

Hatco.
Order Hatco stock item:

18" Sheet Pan

(18" x 26" [457 mm x 660 mm])

Full-Size 18" Sheet Pan

Alum Pan

(18" x 13" [457 mm x 330 mm])

Half-Size Sheet Pan

Summary of Contents for FLAV-R-SAVOR FS2HAS Series

Page 1: ...Este manual contiene importante información sobre seguridad concerniente al mantenimiento uso y operación de este producto Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor Almacenar este manual en una localización segura para la referencia futura Ne pas utiliser cet équipement sans avoir lu et compris le contenu de ce manuel Le non respect des instructions ...

Page 2: ...wner Information 2 Introduction 2 Important Safety Information 3 Model Description 4 All models 4 FS2HAC 2PT model 4 FS2HAC 4PT model 4 Model Designation 4 Specifications 5 Plug Configurations 5 Electrical Rating Chart 5 Dimensions 6 Installation 7 General 7 Installing 4 102 mm Legs 7 Record the model number serial number voltage and purchase date of the unit in the spaces below specification labe...

Page 3: ...cool before performing any cleaning adjustments or maintenance DO NOT submerge or saturate with water Unit is not waterproof Do not operate if unit has been submerged or saturated with water Unit is not weatherproof Locate unit indoors where ambient air temperature is a minimum of 70 F 21 C Do not steam clean or use excessive water on unit This unit is not jet proof construction Do not use jet cle...

Page 4: ... Curtain Cabinets is 190 F 87 C The units can be sealed to the countertop or equipped with 4 102 mm legs FS2HAC 2PT Model The FS2HAC 2PT is a two pan pass through style unit that allows for food product access from either side The unit is capable of holding two full size sheet pans FS2HAC 2PT model Power I O on off Switch Warning Light Crumb Tray FS2HAC 4PT Model The FS2HAC 4PT is a four pan pass ...

Page 5: ...sh Electrical Rating Chart Plug Configurations Units are supplied from the factory with an electrical cord and plug installed plugs are supplied according to the applications Some export units may require field installation of the proper plug ELECTRIC SHOCK HAzARD Plug unit into a properly grounded electrical receptacle of the correct voltage size and plug configuration If plug and receptacle do n...

Page 6: ... 4 102 mm 22 1 8 562 mm 30 1 8 765 mm Cabinet Openings FS2HAC 2PT 18 1 8 W x 8 1 4 H 461 x 235 mm FS2HAC 4PT 18 1 8 W x 16 1 4 H 461 x 438 mm SPECIFICATIONS 6 Form No FS2HACm 0815 English Dimensions C A G F Front View Side View D E B Dimensions FS2HAC 4PT shown with legs included NOTE Specification label located on the top of the unit See label for serial number and verification of unit electrical...

Page 7: ... plug and receptacle do not match contact a qualified electrician to determine and install proper voltage and size electrical receptacle Units supplied without an electrical plug require field installation of proper plug Plug must be properly grounded and of correct voltage size and configuration for electrical specifications of unit Contact a qualified electrician to determine and install proper ...

Page 8: ...et Pan WARNING Digital Temperature Controller 5 Allow the unit to reach the setpoint temperature before loading preheated food product onto the sheet pans NOTE If the warning light illuminates during operation a blower malfunction has occurred Turn off unit and contact an Authorized Service Agent or Hatco for assistance Shutdown 1 move the Power I O on off switch to the O off position and allow th...

Page 9: ...Screws Heat duct cover in closed position FS2HAC 2PT Model The FS2HAC 2PT model has a two sheet pan capacity When two sheet pans are being used Access the food product by reaching in with tongs and pulling the pan approximately half way out of the unit Serve the food product and then push the sheet pan back into the unit with tongs make sure the pan is behind the line next to the arrow inside each...

Page 10: ...the bright finish of the unit it is recommended that the exterior and interior surfaces be cleaned daily Use non abrasive cleaners and cloths only Abrasive cleaners and cloths could scratch finish of unit marring its appearance and making it susceptible to soil accumulation WARNING NOTICE 1 move the Power I O on off switch to the O off position and allow the unit to cool NOTE A cooling fan inside ...

Page 11: ...helf and the other two shelves above No sheet pan on bottom shelf Place a pan on the bottom shelf Imbalanced improper air flow in building Identify air flow sources and make necessary changes move any portable fans Close all windows and doors Close drive thru window Check ceiling vents and redirect if necessary Install flip up panel accessory onto cabinet Defective component Contact Authorized Ser...

Page 12: ...ght hinge bracket for the flip up panel with the right pan support screw hole Installing a Flip Up Panel 5 Insert the right pan support screw through the hinge bracket through the pan support and into the cabinet wall Tighten securely 6 Remove one of the hinge screws from the panel hinge at the top of the flip up panel 7 Insert the hinge screw remaining on the panel hinge into one of the hinge bra...

Page 13: ...ER INTELLECTUAL PROPERTY RIGHT INFRINGEmENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights heat lamp bulbs coated halogen light bulbs halogen heat lamp bulbs xenon light bulbs LED light tubes glass components and fuses Product failure in booster tank fin tube heat exchanger or other water heating equipment caused by ...

Page 14: ...ntes pour le Propriétaire 14 Introduction 14 Consignes de Sécurité Importantes 15 Description du Modèle 16 Tous les modèles 16 FS2HAC 2PT modèle 16 FS2HAC 4PT modèle 16 Désignation du Modèle 16 Caractéristiques Techniques 17 Configuration des Fiches 17 Tableau des valeurs nominales électriques 17 Dimensions 18 Installation 19 Généralités 19 Installation des pieds de 102 mm 4 19 Notez le numéro de ...

Page 15: ...fonctionnement sain AVERTISSEMENT ATTENTION AVIS DANGER DE DÉCHARGE ÉLECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se correspondent pas s adresser à un électricien qualifié pour déterminer et installer une prise de courant de format et de tension corrects Les appareils fournis sans fiche él...

Page 16: ...chauffé Flav R Savor est de 87 C 190 F Les appareils peuvent être fixés sur le comptoir ou équipés de pieds de 102 mm 4 Modèle FS2HAC 2PT Le FS2HAC 2PT est un modèle à deux plaques du type ouvert des deux côtés pour permettre le passage des plats L appareil capable de contenir deux plaques à pâtisserie grande taille FS2HAC 2PT modèle Interrupteur d alimentation I O marche arrêt Témoin Plateau à mi...

Page 17: ...s Les appareils sont livrés avec un cordon électrique avec fiche différentes fiches sont fournies selon les applications Certains appareils pour l exportation pourront exiger l installation sur site de la fiche correcte DANGER DE DÉCHARGE ÉLECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se co...

Page 18: ...moire FS2HAC 2PT 461 L x 235 H mm 18 1 8 W x 8 1 4 H FS2HAC 4PT 461 L x 438 H mm 18 1 8 W x 16 1 4 H CARACTÉRISTIQUES TECHNIQUES Français 18 Formulaire n FS2HACm 0815 Dimensions C A G F Vue de face Vue de côté D E B Dimensions FS2HAC 4PT montré Ajouter 102 mm 4 à la hauteur D lorsque les jambes de 102 mm 4 sont installées NOTA situé sur l appareil Reportez vous à l étiquette du numéro de série et ...

Page 19: ...ormat et de configuration des broches corrects Si la fiche et la prise ne se correspondent pas s adresser à un électricien qualifié pour déterminer et installer une prise de courant de format et de tension corrects Les appareils fournis sans fiche électrique demandent l installation de la fiche correcte La fiche doit être correctement mise à la terre et de tension taille et configuration correctes...

Page 20: ...t de consigne de température dans cette section Flèche Interrupteur d alimentation I O marche arrêt Témoin Plaque grande taille AVERTISSEMENT ATTENTION NOTA Le régulateur de température numérique est préréglé en usine sur un point de consigne de température de 87 C 190 F Une fois que vous avez modifié le point de consigne de température le nouveau point de consigne de température sera mémorisé jus...

Page 21: ...s peuvent être chargé et déchargés d un côté ou de l autre Vis desserrées Vis serrées Couvercle de la conduite chauffante en position ouverte Couvercle de la conduite chauffante en position fermée Tous les modèles Toujours garder une plaque grande taille ou deux plaques de la demi taille sur l étagère inférieure Assurez vous que toutes les plaques sont derrière la ligne à côté de la flèche à l int...

Page 22: ...matériel Hatco AVERTISSEMENT Nettoyage quotidien Afin de préserver la finition brillante de l armoire Flav R Savor il est recommandé de nettoyer quotidiennement les surfaces extérieures et intérieures Utilisez uniquement des nettoyants non abrasifs et des chiffons doux Les chiffons et nettoyants abrasifs risquent de rayer la finition de l appareil d altérer son apparence et de le rendre vulnérable...

Page 23: ...VERTISSEMENT Vous avez des questions en ce qui concerne les pannes Si le problème persiste veuillez contacter l agence d entretien agréée Hatco la plus proche ou Hatco pour obtenir une assistance Pour trouver l agence d entretien la plus proche rendez vous sur le site Internet de Hatco www hatcocorp com et cliquez sur Trouver un agent d entretien ou contactez l équipe d entretien et de pièces déta...

Page 24: ...que l appareil ait le temps d atteindre la température du point de consigne Pas de plaque sur l étagère la plus basse Placez une plaque sur l étagère la plus basse Débit d air inadéquate déséquilibré dans le bâtiment Identifier les sources de débit d air et apporter les changements nécessaires Déplacez tous les ventilateurs portatifs Fermez toutes les fenêtres et portes Fermer la fenêtre volante V...

Page 25: ...charnière droite pour le panneau rabattable avec le trou de la vis de support de la plaque droite Installation d un panneau rabattable 5 Insérez la vis du support de la plaque droite à travers la charnière puis le support de plaque et dans la paroi de l armoire Serrez fermement 6 Retirez l une des vis de charnière de la charnière de plaque en haut du panneau rabattable 7 Insérez la vis de charnièr...

Page 26: ...A PROPRIÉTÉ INTELLECTUELLE Sans restreindre la portée générale des énoncés précédents CES GARANTIES NE COUVRENT PAS Ampoules d éclairage à incandescence enduites lumières fluorescentes ampoules de lampes chauffantes ampoules d éclairage à halogène enduites ampoules de lampes chauffantes au xénon tubes d éclairage DEL composants en verre et fusibles défaut de produit dans la cuve d un appareil de c...

Page 27: ...NOTES Français Formulaire n FS2HACm 0815 27 ...

Page 28: ...ppliance Installation Buffalo 716 884 7425 Duffy s Equipment Services Inc Buffalo 800 836 1014 3Wire Northern Plattsburgh 800 634 5005 Duffy s Equipment Services Inc Sauquoit 800 836 1014 J B Brady Inc Syracuse 315 422 9271 NORTH CAROLINA Authorized Appliance Charlotte 704 377 4501 OHIO Akron Canton Comm Svc Inc Akron 330 753 6634 Service Solutions Group Cincinnati 513 772 6600 Commercial Parts an...

Reviews: