MAINTENANCE
The Hatco Flav-R-Savor Large Capacity Holding and
Display Cabinets are designed for maximum durability
and performance, with minimum maintenance. The rack
motor is permanently lubricated and requires no
maintenance. The blower motor requires lubrication
every 3 months.
See Figure 12.
LUBRICATING THE BLOWER MOTOR
WARNING
1. Turn the power switch off and unplug unit from
power source.
2. Remove the screws at each corner of the top
painted cover and lift off.
3. Remove motor bearing oil plugs (A), add 6 drops of
oil (use Hatco part #05-01-019) and replace plugs.
4. Rotate access cover on top of air chamber to oil
blower bearing (B). Remove plug, add 6 drops of oil
and replace.
5. Replace top cover and four (4) corner screws.
ROTISSERIE CHAIN ADJUSTMENT
The rotisserie drive chain adjustment should be cleaned
and adjusted (if needed) every three months.
WARNING
1. Turn the power switch off and unplug the unit from
its power source.
2. Remove the screws at each corner of the top painted
cover and lift off.
3. Locate the rotisserie drive motor (right side of unit).
4. Loosen four 10-32 hex head bolts securing rotisserie
drive motor to the motor bracket.
5. Remove slack in chain by pulling rotisserie drive
motor up.
6. While holding rotisserie motor up against chain,
tighten hex bolts.
7. Replace and secure the exterior top cover onto unit.
8. Plug the cabinet power cord into its power source.
REMOVING LIME & MINERAL DEPOSITS
NOTE:
If the water used has an excessive amount
of lime or mineral content, follow the instructions listed
below for periodic cleaning and deliming of the water
reservoir.
WARNING
1.
Turn the power switch off and unplug the unit
from its power source.
2.
After the unit has cooled down, drain all
remaining water out of the unit.
3.
Fill the unit with a mixture of water and delimer.
NOTE:
The delimer used should be a safe, non-toxic,
non-corrosive solution. Follow the delimer’s instructions
for proper mixture of water and delimer solution.
4. Allow the unit to stand with the mixture in the
reservoir for the recommended period of time. (The
time required will vary depending on the solution
used and amount of deposits in the reservoir.)
5. After the deliming period, drain the solution from
the tank.
6. Continue to fill and drain the unit with water only,
until the discharge is clear.
7. Plug the cabinet power cord into its power source
and fill the unit as usual for daily operation.
NOTE:
How often this procedure must be performed
depends on the lime and mineral content of the water
used for daily operation.
DISPLAY LIGHT BULB REPLACEMENT
The display light is an incandescent light bulb which
illuminates the warming area. This bulb has a special
coating to guard against injury and food contamination
in the event of breakage.
To replace a light bulb, disconnect the power supply and
wait until the unit has cooled. Display light bulbs have a
threaded base. Unscrew the light bulb from the unit and
replace it with a new specially coated incandescent bulb.
Hatco shatter-resistant light bulbs meet N.S.F. standards
for food holding and display areas. Use Hatco part
#02.30.043.00.
WARNING:
Only bulbs which meet or exceed N.S.F. standards,
specifically designed for food holding areas must be
used. Breakage of bulbs not specially coated could result
in personal injury and/or food contamination.
Figure 12. Blower Fan Oil Procedure.
9
Form No. WFSTM-0297