background image

Important Owner Information ..............................................2

Introduction...........................................................................2

Important Safety Information...............................................3

Model Description.................................................................4

Model Designation................................................................5

Specifications........................................................................5

Plug Configurations .............................................................5

Electrical Rating Chart—3CS2 Models................................5

Electrical Rating Chart—FR2 Models..................................6

Dimensions ..........................................................................7

NSF Criteria .........................................................................7

Installation.............................................................................8

General ................................................................................8

Sizing Information ................................................................8

Installing the Unit .................................................................8

Electrical Information ...........................................................9

Operation.............................................................................10

General ..............................................................................10

Maintenance ........................................................................11

General ..............................................................................11

Daily Cleaning....................................................................11

Draining Heater for Service Protection ..............................11

Troubleshooting Guide ......................................................12

Error Codes .......................................................................12

Options and Accessories ..................................................13

Limited Warranty.................................................................15

Authorized Parts Distributors............................Back Cover

IMPORTANT OWNER INFORMATION

Record the model number, serial number (located on the lower

right side toward the front of the unit), voltage and purchase

date of your Water Heater in the spaces below. Please have

this  information  available  when  calling  Hatco  for  service

assistance.
Model No. ____________________________________
Serial No. ____________________________________
Voltage ______________________________________
Date of Purchase ______________________________

Register your unit!

Completing online warranty registration will prevent delay in

obtaining warranty coverage. Access the Hatco website at

www.hatcocorp.com

, select the 

Parts & Service

pull-down

menu, and click on “Warranty Registration”.

Business

Hours:

7:00 

AM

to 5:00 

PM

Central Standard Time (CST)

(Summer Hours:  June to September

7:00 

AM

to 5:00 

PM

CST Monday

Thursday

7:00 

AM

to 4:00 

PM

CST Friday)

Telephone: 800-558-0607; 414-671-6350
e-mail:

partsandservice@hatcocorp.com

Additional information can be found by visiting our web site at

www.hatcocorp.com

.

24 Hour 7 Day Parts and Service

Assistance available in the United States

and Canada by calling 800-558-0607.

INTRODUCTION

Form No. HHM-0517

2

CONTENTS

Hatco 3CS2 Hydro-Heater Sanitizing Sink Heaters and FR2

Hydro-Heater  Food  Rethermalizers/Bain-Marie  Heaters  are

designed to supply temperature-controlled water to a sink or

holding vessel located above the heater. Water flows by natural

convection from the holding vessel directly into a tubular water

chamber with heating elements uniquely wrapped around the

outside of the flow tube. The heating elements do not come in

direct  contact  with  the  water,  reducing  sediment  and  lime

buildup on the element and resulting in longer life. The heated

water flows upward and returns to the holding vessel. 
A  special  electronic  controller  maintains  the  setpoint

temperature ensuring a responsive and efficient operation. The

unit’s electrical and plumbing connections are factory-assembled

and ready for installation.
Hatco Hydro-Heaters are products of extensive research and

field testing. The materials used were selected for maximum

durability, attractive appearance and optimum performance.

Every unit is inspected and tested thoroughly prior to shipment.

This manual provides the installation, safety, and operating

instructions for the Hydro-Heater Sanitizing Sink Heaters and

Food Rethermalizers/Bain-Marie Heaters. Hatco recommends

that all installation, operating, and safety instructions appearing

in this manual be read prior to installation or operation of a unit.
Safety information that appears in this manual is identified by

the following signal word panels:

WARNING indicates a hazardous situation which, if not

avoided, could result in death or serious injury.

CAUTION  indicates  a  hazardous  situation  which,  if  not

avoided, could result in minor or moderate injury.

NOTICE  is  used  to  address  practices  not  related  to

personal injury.

CAUTION

NOTICE

WARNING

Summary of Contents for FR2 Series

Page 1: ...lla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Este manual contiene importante informaci n sobre seguridad concerniente al mantenimient...

Page 2: ...lable in the United States and Canada by calling 800 558 0607 INTRODUCTION Form No HHM 0517 2 CONTENTS Hatco 3CS2 Hydro Heater Sanitizing Sink Heaters and FR2 Hydro Heater Food Rethermalizers Bain Mar...

Page 3: ...trical shock or burn Genuine Hatco Replacement Parts are specified to operate safely in the environments in which they are used Some aftermarket or generic replacement parts do not have the characteri...

Page 4: ...CS2 FR2 Series Hydro Heater Electronic Controller POWER ON OFF I O Switch Drain Handle closed Outlet Inlet Drain Clean out Drain Units are voltage specific Refer to specification label for electrical...

Page 5: ...ctory with an electrical cord and plug installed Plugs are supplied according to the applications ELECTRIC SHOCK HAzARD For units with an electrical cord and plug plug unit into a properly grounded el...

Page 6: ...3 Bal 9 6 14 15 24 lbs 11 kg FR2 6B 208 6 0 3 Bal 16 7 12 30 27 lbs 12 kg 240 6 0 3 Bal 14 5 12 20 27 lbs 12 kg FR2 9B 208 9 0 3 Bal 25 10 40 27 lbs 12 kg 240 9 0 3 Bal 21 7 10 30 27 lbs 12 kg Electri...

Page 7: ...o be incorporated into a hot water bath rethermalizer Hatco does not supply the vessel that contains the water nor the system that determines how food is placed and held in the vessel The Hatco FR2 un...

Page 8: ...n electrical cord and plug require a hardwired connection to on site electrical system Connection must be properly grounded and of correct voltage size and configuration for electrical specifications...

Page 9: ...se or pipe may be connected to the heater drain and run to an open sight drain The heater drain should not be permanently connected to the sanitary drain system The clean out brush must have access to...

Page 10: ...f 190 F 88 C Use appropriate protection when operating unit DO NOT set temperature control higher than 190 F 88 C Units are designed to heat water up to 190 F 88 C Water over 190 F 88 C is very active...

Page 11: ...rd until it is in the horizontal position and allow all water to drain Unscrew and remove the pipe cap s from the clean out drain s and allow all water to drain if applicable 5 Wipe visible deposits f...

Page 12: ...ER ON OFF I O switch to the OFF O position and then to the ON I position Fuses may be blown the circuit breaker may be tripped or the power cord may be unplugged Check for proper fuse sizing and repla...

Page 13: ...nd must conform with all federal state and local codes Do not exceed an incoming water temperature of 140 F 60 C or incoming water pressure of 80 psi 550 kPa 1 Make sure the POWER ON OFF I O switch is...

Page 14: ...h and adapter Use the following procedure to power flush the unit 1 Move the POWER ON OFF I O switch to the OFF O position and allow the unit and water to cool 2 Connect one end of a drain hose onto t...

Page 15: ...ROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights heat lamp bulbs coated halogen light bulbs h...

Page 16: ...a 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfield 973 575 9145 Service Plus Flanders 973 691 630...