Form No. GRFSm-0815
8
INSTALLATION
English
Assembly
1. Remove the top housing and the post mount from the
carton and set parts on a non-scratching surface.
2. Remove all packaging materials from the unit.
3. Position the top housing, element side up, on a non-
scratching surface.
4. Secure the mounting post to the top housing.
a. Loosen the screw located near the top of the post
mount.
b. For non-corded units: Insert UL Recognized wiring
through the top end of the post mount. Wires need to
be pulled completely through the post mount, exiting out
the threaded end of the post mount.
c. Slide the post mount onto the top housing and secure by
tightening the screw.
Securing mounting Post to Top Housing
NOTE: Post mount will rotate slightly on the top housing for
proper swing away operation.
5. mount the unit to the countertop.
a. Drill a 1" (25 mm) diameter hole in the countertop in the
desired location.
b. Secure the unit using the washers, bolt, and nut
provided.
mounting Unit to Countertop
ON
OFF
Washer
Washer
Nut
Bolt
Countertop
Screw
Post
Mount
Top
Housing
General
Hatco Glo-Ray
®
Fry Station Foodwarmers are shipped with
most components installed and ready for operation. The
following installation instructions must be performed before
operating the unit.
ELECTRIC ShOCK hAzARD: Unit is not weatherproof.
Locate unit indoors where the ambient air temperature is a
minimum of 70°F (21°C).
FIRE hAzARD: Locate unit a minimum of 3″ (76 mm) from
combustible walls and materials. If safe distances are not
maintained, discoloration or combustion could occur.
Locate unit at the proper counter height in an area that is
convenient for use. The location should be level to prevent
the unit or its contents from falling accidentally and strong
enough to support the weight of the unit and contents.
1. Remove the unit from the carton.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
ImPORTaNT OWNER INFORmaTION
section for
details.
2. Remove tape and protective packaging from all surfaces of
the unit and any accessories.
Electrical Information
Refer to the appropriate “Electrical Rating Chart” in the
SPECIFICaTIONS section for unit-specific information.
Non-corded units must be installed by a qualified
electrician. Installation must conform to all local electrical
codes. Installation by unqualified personnel will void unit
warranty and may lead to electric shock or burn, as well as
damage to unit and/or its surroundings.
Install an approved, grounded receptacle to match the plug and
cord supplied with the unit, if necessary.
CAUTION
WARNING
WARNING