OPERATION

Form No. GRHWm-0111

9

GRHW-1SGD and GRHW-1SGDS 

1. move the Power On/Off switch to the “On” position.

• The overhead lights will turn on, the overhead heating

element will turn on, the heated glass shelf will energize,

and the base heating element will energize.

2. Turn  the  base  heat  control  to  the  desired  temperature

setting.

3. Turn the glass shelf heat control to the desired setting.

Figure 15. Controls for GRHW-1SGD and GRHW-1SGDS 

(GRHW-1SDS controls shown)

Shutdown

GRHW-1P, -2P, -1SG, and -1SGS 

1. move the Power ON/OFF switch on the base to the OFF

position. The overhead lights and heated base will shut off.

2. If the unit is equipped with an ON/OFF (I/O) toggle switch or

an overhead heat control in the upper housing, move the

switch to the OFF (O) position or turn the control to the off

(O) position. The overhead heating element will shut off.

3. If the unit is equipped with both an ON/OFF (I/O) toggle

switch and an overhead heat control in the upper housing:

• move the ON/OFF (I/O) toggle switch to the OFF (O)

position. The overhead lights will turn on.

• Turn the overhead heat control to the off (O) position.

The overhead heating element will shut off.

GRHW-1SGD and GRHW-1SGDS 

1. move the Power On/Off switch to the “Off” position. The

overhead lights, overhead heating element, heated glass

shelf, and heated base will shut off.

NOTE: Refer to the MAINTENANCE section for Ground Fault

Circuit Interrupt (GFCI) switch information.

Glass Shelf

Heat Control

Ground Fault

Circuit Interrupter

(GFCI)

Base Heat

Control

Power On/Off

Switch

General

Use the following procedures to operate the Glo-Ray® GRHW

Series mini-merchandisers.

Read  all  safety  messages  in  the  IMPORTANT  SAFETY

INFORMATION section before operating this equipment.

Startup 

Perform the following step for startup of all GRHW models and

then proceed to the appropriate section for the remaining steps

for startup.

1. Plug unit into a properly grounded electrical receptacle of

the correct voltage, size and plug configuration. See the

SPECIFICaTIONS section for details.

GRHW-1P, -2P, -1SG, and -1SGS

1. move the Power ON/OFF rocker switch on the base to the

ON position. The base heat control will energize and the

overhead lights will turn on.

2. Turn  the  base  heat  control  to  the  desired  temperature

setting. The base temperature range is from 82°F to 200°F

(28°C to 93°C).

Figure 13. Base controls for GRHW-1P, -2P, -1SG, and -1SGS

3. If the unit is equipped with an ON/OFF (I/O) toggle switch or

an overhead heat control in the upper housing, move the

switch to the ON (I) position or turn the control to the desired

setting. The overhead heating element will energize.

4. If the unit is equipped with both an ON/OFF (I/O) toggle

switch and an overhead heat control in the upper housing:

• move  the  ON/OFF  (I/O)  toggle  switch to  the  ON  (I)

position. The overhead lights will turn on.

• Turn the overhead heat control to the desired setting.

The overhead heating element will energize.

Figure 14. Top controls for GRHW-1P, -2P, -1SG, and -1SGS

WARNING

ON/OFF (I/O)

Toggle Switch

Overhead

Heat Control

(optional)

Power ON/OFF

Switch

Base Heat

Control

Summary of Contents for Glo-Ray GRHW-1SGD Series

Page 1: ...de este manual por favor pregunte a su supervisor Almacenar este manual en una localizaci n segura para la referencia futura Do not operate this equipment unless you have read and understood the conte...

Page 2: ...tant Safety Information 3 Model Description 4 all models 4 Model Designation 5 Specifications 5 Plug Configurations 5 Electrical Rating Chart 5 Dimensions 6 Installation 7 General 7 Installing the Sne...

Page 3: ...en or persons with reduced physical sensory or mental capabilities Ensure proper supervision of children and keep them away from the unit Make sure all operators have been instructed on the safe and p...

Page 4: ...controlled heated base a sneeze guard overhead infrared heating elements overhead display lights optional Designer colors and a 6 1829 mm cord and plug set NOTE Refer to the OPTIONS AND ACCESSORIES s...

Page 5: ...No GRHWm 0111 5 Figure 4 model Designation G R H W X P Glo Ray P Pans SG Single Horizontal Shelf SGS Single Slanted Shelf SGD Dual Horizontal Shelf with Heated Glass Upper Shelf SGDS Dual Slanted She...

Page 6: ...65 mm 19 1 8 486 mm 18 1 4 464 mm 19 7 8 505 mm 11 3 8 289 mm GRHW 1SGD 22 7 8 581 mm 20 1 2 521 mm 23 1 2 597 mm 19 7 8 505 mm 11 3 8 289 mm GRHW 1SGDS 22 3 4 578 mm 21 534 mm 23 5 8 600 mm 19 7 8 50...

Page 7: ...uld be taken when unpacking shipping carton to avoid damage to unit and components enclosed ELECTRIC SHOCK HAzARD unit is not weatherproof Locate unit indoors where the ambient air temperature is a mi...

Page 8: ...rresponding holes in the two support posts make sure the slanted edge of the side panel is aligned with the sneeze guard Sneeze Guard Stud Support Trim Cap Nut 2 Secure the side panel to the support p...

Page 9: ...lf Heat Control Ground Fault Circuit Interrupter GFCI Base Heat Control Power On Off Switch General Use the following procedures to operate the Glo Ray GRHW Series mini merchandisers Read all safety m...

Page 10: ...g a standard ceramic glass stove top cleaner NOTICE WARNING Replacing Display Light Bulbs use only light bulbs that meet or exceed National Sanitation Foundation NSF standards and are specifically des...

Page 11: ...for assistance Base heating element not working Contact authorized Service agent or Hatco for assistance Excessive air movement around warming cabinet Relocate unit or redirect air movement i e air c...

Page 12: ...erhead lights will turn on the overhead heating element will turn on the heated glass shelf will energize and the base heating element will energize CAuTION Some exterior surfaces on the unit will get...

Page 13: ...lder through the mounting holes on the front and rear long sign holder brackets Figure 20 Installing a Side Sign Holder b Secure the side sign holder to the two long sign holders by attaching the supp...

Page 14: ...S FOR a PaRTICULaR PURPOSE OR PaTENT OR OTHER INTELLECTUaL PROPERTY RIGHT INFRINGEmENT Without limiting the generality of the foregoing SUCH WaRRaNTIES DO NOT COVER Coated incandescent light bulbs flu...

Page 15: ...NOTES Form No GRHWm 0111 15...

Page 16: ...06 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfield 973 575 9145 Service Plus Flanders 973 691 6300 NEW YORK acme american Repairs Inc Brooklyn 718 456 6544 alp...

Reviews: