Form No. GR2AM-1116
14
INSTALLATION
English
General
Hatco Glo-Ray
®
Designer
Infrared Foodwarmers are shipped
with most components pre-assembled. Care should be taken
when unpacking the shipping carton to avoid damage to the
unit and components enclosed.
ELECTRIC SHOCK HAzARD: All electrical connections
must be in accordance with local electrical codes and any
other applicable codes. Connections should be made by a
qualified, licensed electrician.
FIRE HAzARD:
• Locate unit the correct distance from combustible walls
and materials. If safe distances are not maintained,
discoloration or combustion could occur. Refer to
specific installation and mounting information in this
manual for proper clearances.
• Make sure to follow the installation information listed
below for specific food warmers. If safe distances are not
maintained, discoloration or combustion could occur.
a. Do not install standard wattage food warmers (GR2A,
and GR2AL Series) less than 17″ (432 mm) above
combustible surfaces.
b. Do not install high wattage food warmers (GR2AH)
less than 20″ (508 mm) above combustible surfaces.
c. Do not install high wattage food warmers with lights
(GR2AHL Series) less than 22″ (559 mm) above
combustible surfaces.
d. Do not install dual food warmers (GR2A-XXD Series)
less than 27″ (689 mm) above combustible surfaces.
e. Do not install high wattage, dual food warmers
(GR2AH-XXD and GR2AHL-XXD Series) less than 32″
(813 mm) above combustible surfaces.
f. Install all
Designer
food warmers with a minimum
distance of 6″ (152 mm) from a combustible wall or
adjacent surface.
Do not lay unit on the front or back side. Damage to the
unit could occur.
WARNING
NOTICE
1. Remove the unit from the carton.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION
section for details.
2. Remove tape and protective packaging from all surfaces of
unit.
3. With non-adjustable stand cover removed, attach non-
adjustable stands on each end of unit using supplied screws.
• Loosen angled bracket screws to slide bracket tight to stand.
Installing Non-Adjustable Stand to Unit
4. Mark the holes on the mounting surface using the
“Mounting Dimensions” illustration below. All models have
one conduit hole except models listed below.
• Two Conduit Holes: All Tandem units,
GR2AH-XXD (60–84″), GR2AL-XXD (84″), and
GR2AHL-XXD (60–84″)
Mounting Dimensions
5. Drill the marked holes.
• The bolt holes are 1/4" diameter.
• The conduit hole(s) are 1" diameter.
Front View
Overall Width
minus
2-7/16'' (62 mm)
Bottom View - Mounting Flange
2''
(51 mm)
15/16''
(24 mm)
Conduit
Holes
3''
(76 mm)
2''
(51 mm)
Bolt Hole
Bolt Hole
Screws
Non-Adjustable Stand
Angled
Bracket