8
Form No. HWBIM-0319
English
Model
Voltage
Circuit
Watts
Amps
Phase
Plug
Configuration
Shipping
Weight*
HWBLI-1
120
1
750
6.3
1
NEMA 5-15P
38 lbs. (17 kg)
HWBI-1 and
HWBI43-1
**
120
1215
10.1
208
1215
5.8
NEMA 6-15P
240
1215
5.1
220
–
230
1
1215–1328
5.5–5.8
1
N/A
38 lbs. (17 kg)
230
–
240
1116–1215
4.9–5.1
HWBLI-2
120
1
1500
12.5
1
NEMA 5-20P
73 lbs. (33 kg)
HWBI-2 and
HWBI43-2
208
2415
11.6
NEMA 6-15P
2415
10.1
3
N/A
240
2415
10.1
1
NEMA 6-15P
2415
8.7
3
N/A
220
–
230
1
2415–2640
11.0–11.5
1
N/A
73 lbs. (33 kg)
230
–
240
2218–2415
9.6–10.1
HWBLI-3
120
1
2250
18.8
1
NEMA 5-30P
103 lbs. (47 kg)
HWBI-3 and
HWBI43-3
208
3615
17.4
NEMA 6-30P
3615
10.1
3
N/A
240
3615
15.1
1
NEMA 6-20P
3615
8.8
3
N/A
220
–
230
1
3615–3951
16.4–17.2
1
N/A
103 lbs. (47 kg)
230
–
240
3320–3615
14.4–15.1
Minimum
Maximum
Water Pressure
25 psi (172 kPa) 100 psi (689 kPa)
Water Temperature
35°F (2°C)
110°F (43°C)
SPECIFICATIONS
Water Supply Specifications (Auto-Fill Units)
NEMA 6-50P
NEMA 6-30P
NEMA 6-20P
NEMA 6-15P
NEMA 5-15P
NEMA 5-20P
NEMA 5-30P
Plug Configurations
NOTE: Receptacle not supplied by Hatco.
Plug Configurations
Some units are supplied from the factory with an electrical
cord and plug installed. Plugs are supplied according to the
application. Refer to the OPTIONS AND ACCESSORIES
section for more information.
WARNING
ELECTRIC SHOCK HAZARD: Plug unit into a properly
grounded electrical receptacle of the correct voltage,
size, and plug configuration. If plug and receptacle do not
match, contact a qualified electrician to determine and
install proper voltage and size electrical receptacle.
NOTE: Specification label located on side of the unit. See
label for serial number and verification of unit electrical
information.
Electrical Rating Chart
The shaded areas contain electrical information for
International models only
.
NOTE: Shipping weight includes packaging.
*
Add 3 lbs. (1.4 kg) for “D” and “DA” models.
**
Model HWBI43-1 not available in 120V.