OPTIONS AND ACCESSORIES

English

Flip-Up Doors

Flip-up doors are available for all models as an added option at

the time of order. Flip-up doors can be installed on each shelf

on either the customer side or operator side of the unit. Use

the following procedure to install flip-up doors (the procedure is

the same for either side as well as each shelf).

1. align the screw holes at each end of the flip-up door hinge

with the mounting hole in each end plate on the unit.

2. Insert a hinge screw through each end plate and into the

flip-up door.

3. Tighten the hinge screws until the flip-up door is secure.

Do not over-tighten the screws.

Flip-Up Door Installation

Sneeze Guards

Sneeze guards are available for all models as an added option

at  the  time  of  order.  Sneeze  guards  are  installed  by  re-

positioning flip-up doors and securing with a bracket.

1. Install the flip-up door. Refer to “Flip-Up Doors” in this section. 
2. Remove the two screws from the end plate on each side

of the unit. 

3. Rotate up and hold the flip-up door in the sneeze guard

position. 

4. align the holes on one of the sneeze guard brackets with

the end plate screw holes and slide the bracket onto the

flip-up door. 

5. Install the end plate screws through the sneeze guard

bracket and into the end plate. Tighten securely.

6. Repeat steps 2–5 on the other side of the unit.

Sneeze Guard Installation

Flip-Up Door

Hinge

Screw

Mounting

Hole

Hinge

Flip-up door

rotated to

sneeze guard

position.

Flip-up door

rotated to

sneeze guard

position.

Sneeze Guard

Bracket

Sneeze Guard

Bracket

End Plate Screw

Digital Temperature Controller

Units  may  be  equipped  with  optional  digital  temperature

controllers that regulates and displays the base temperature(s).

Use the following procedures to operate the digital temperature

controller.

NOTE: This option is factory installed only, not available for

retrofit.

NOTE: Units manufactured for use outside the United States

and Canada will have digital temperature controllers

that indicate temperature in Celsius (°C).

Digital Temperature Controller

1. move the unit Power I/O (on/off) switch(es) to the I (on)

position. 

• The digital temperature controller will energize and the

current temperature of the heated base(s) will appear

on the display. 

CAUTION!  Some exterior surfaces on

the unit will get hot. Use caution when touching

these areas.

• The phrase “out 1” will appear in the upper left corner of

the display to show that the base is in heat mode.

2. Press  and  release  the 

key. The  current  setpoint

temperature will be shown on the display and ”out 1” will

flash in the upper left corner.

3. Press the 

key or 

key within 15 seconds to

change  the  setpoint  temperature.  If  no  key  is  pressed

within 15 seconds, the display will revert to the current

temperature of the heated base(s)

4. Press the 

key or wait 15 seconds to lock in the new

setpoint temperature. The setpoint temperature range of

the controller is from room temperature to the maximum

operating temperature of the unit.

Locking/Unlocking the Digital Temperature

Controller

The keys on the digital temperature controller can be locked to

prevent unauthorized changes to the settings.
To lock the keys of the digital temperature controller:

• Press and hold both the 

key and 

key at the

same time for over two seconds. The message “Loc” will

appear on the display.

To unlock the keys of the digital temperature controller:

• Press and hold both the 

key and 

key at the

same time until the message “UnL” appears on the display.

Down Arrow

Key

Up Arrow

Key

“out 1”

Fahrenheit

Symbol

SET

Key

Summary of Contents for HXMH Series

Page 1: ...lesi n o muerte Este manual contiene importante informaci n sobre seguridad concerniente al mantenimiento uso y operaci n de este producto Si usted no puede entender el contenido de este manual por f...

Page 2: ...X and HXmH XXD models 4 HXmS XX and HXmS XXD models 4 Model Designation 4 Specifications 5 Plug Configurations 5 Electrical Rating Charts 5 Dimensions HXmH models 7 Dimensions HXmS models 8 Installati...

Page 3: ...ARNING ELECTRIC SHOCK HAzARD Plug unit into a properly grounded electrical receptacle of the correct voltage size and plug configuration If plug and receptacle do not match contact a qualified electri...

Page 4: ...merchandisers designed to hold hot wrapped product They are available in widths from 24 to 60 610 to 1524 mm in 6 152 mm increments and are available in single or dual shelf models HXmH models HXMS X...

Page 5: ...ATIONS English Electrical Rating Chart HXMH XX Models Horizontal Single Shelf Electrical Rating Chart HXMH XXD Models Horizontal Dual Shelf Plug Configurations Units are equipped with an electrical co...

Page 6: ...tts Amps Plug Configuration HXmS 24D 120 1400 11 7 NEma 5 15P HXmS 30D 120 208 240 1800 7 5 NEma L14 20P HXmS 36D 120 208 240 2200 9 2 NEma L14 20P HXmS 42D 120 208 240 2400 10 0 NEma L14 20P HXmS 48D...

Page 7: ...19 483 mm 9 1 2 242 mm HXmH 24D 26 11 16 677 mm 28 9 16 725 mm 32 7 8 835 mm 27 15 16 709 mm 19 483 mm 9 1 2 242 mm HXmH 30D 32 11 16 829 mm 28 9 16 725 mm 32 7 8 835 mm 33 15 16 861 mm 19 483 mm 9 1...

Page 8: ...mm 9 5 16 237 mm HXmS 24D 26 11 16 677 mm 28 3 16 715 mm 32 3 4 831 mm 27 15 16 709 mm 19 483 mm 9 5 16 237 mm HXmS 30D 32 11 16 829 mm 28 3 16 715 mm 32 3 4 831 mm 33 15 16 861 mm 19 483 mm 9 5 16 23...

Page 9: ...n See the ImPORTaNT OWNER INFORmaTION section for details 2 Remove tape and protective packaging from all surfaces of the unit 3 Place the unit in the desired location Locate the unit in an area where...

Page 10: ...lug configuration See the SPECIFICaTIONS section for details 2 move the Power I O on off switch es to the I on position The overhead LED lights will turn on The heated base and overhead heaters will e...

Page 11: ...he Heated merchandiser clean the unit daily Clean unit daily to avoid malfunctions and maintain sanitary operation Use non abrasive cleaners and cloths only Abrasive cleaners and cloths could scratch...

Page 12: ...Hatco for assistance No heat and no light Power turned OFF move Power I O on off switch es to the I on position Circuit breaker tripped Reset circuit breaker If circuit breaker continues to trip cont...

Page 13: ...controllers that regulates and displays the base temperature s Use the following procedures to operate the digital temperature controller NOTE This option is factory installed only not available for r...

Page 14: ...INTELLECTUaL PROPERTY RIGHT INFRINGEmENT Without limiting the generality of the foregoing SUCH WaRRaNTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights heat lamp bulbs coated halogen...

Page 15: ...tantes 16 Description du Mod le 17 Tous les mod les 17 mod les HXmH XX et HXmH XXD 17 mod les HXmS XX et HXmS XXD 17 D signation du Mod le 17 Caract ristiques Techniques 18 Configuration des fiches 18...

Page 16: ...RGE LECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se correspondent pas s adresser un lectri...

Page 17: ...nt des comptoirs rayonnage horizontal con us pour pr senter des produits chauds conditionn s Ils sont disponibles avec une largeur variant de 610 1524 mm 24 60 r glables par incr ments de 152 mm 6 Les...

Page 18: ...iques Mod les HXMH XX Rayonnage horizontal simple Tableau des valeurs nominales lectriques Mod les HXMH XXD Rayonnage horizontal double Configuration des fiches Les appareils sont quip s d un c ble d...

Page 19: ...ches HXmS 24D 120 1400 11 7 NEma 5 15P HXmS 30D 120 208 240 1800 7 5 NEma L14 20P HXmS 36D 120 208 240 2200 9 2 NEma L14 20P HXmS 42D 120 208 240 2400 10 0 NEma L14 20P HXmS 48D 120 208 240 2900 12 1...

Page 20: ...483 mm 19 242 mm 9 1 2 HXmH 24D 677 mm 26 11 16 725 mm 28 9 16 835 mm 32 7 8 709 mm 27 15 16 483 mm 19 242 mm 9 1 2 HXmH 30D 829 mm 32 11 16 725 mm 28 9 16 835 mm 32 7 8 861 mm 33 15 16 483 mm 19 242...

Page 21: ...mm 19 237 mm 9 5 16 HXmS 24D 677 mm 26 11 16 715 mm 28 3 16 831 mm 32 3 4 709 mm 27 15 16 483 mm 19 237 mm 9 5 16 HXmS 30D 829 mm 32 11 16 715 mm 28 3 16 831 mm 32 3 4 861 mm 33 15 16 483 mm 19 237 mm...

Page 22: ...antie compl tez l enregistrement en ligne de votre garantie Lisez la section INFORmaTIONS ImPORTaNTES POUR LE PROPRIETaIRE pour plus de d tails 2 Retirez le ruban et l emballage de protection de toute...

Page 23: ...tion ad quats Consultez la section CaRaCT RISTIQUES pour obtenir plus de d tails 2 Placez l interrupteur I O marche arr t sur la position I marche Les lumi res DEL suspendues s allumeront La base chau...

Page 24: ...itres sur les surfaces en plastique telles que les pare haleine ou les capots rabattables Les serviettes en papier et le nettoyant pour vitres peuvent rayer l quipement Essuyez les surfaces plastique...

Page 25: ...r toute demande d assistance Pas de chaleur ni de lumi re alimentation coup e Placez l interrupteur I O marche arr t sur la position I marche Le coupe circuit a disjonct R initialisez le disjoncteur S...

Page 26: ...es d un thermostat num rique optionnel visant r guler et afficher les temp ratures de la base Observez les proc dures suivantes pour utiliser le thermostat num rique NOTA Cette option sera initialeme...

Page 27: ...OITS DE La PROPRI T INTELLECTUELLE Sans restreindre la port e g n rale des nonc s pr c dents CES GaRaNTIES NE COUVRENT PaS ampoules d clairage incandescence enduites lumi res fluorescentes ampoules de...

Page 28: ...14 890 0700 Kaemmerlen Parts Service St Louis 314 535 2222 NEBRASKA anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 64...

Reviews: