background image

 

INTRODUCTION 

Thank you for choosing the Hatsan Volt Dual-Power Portable PCP Air Compressor! 

Always exercise caution when operating this compressor. It will allow you to fill your PCP airguns with ease.  
Please read the entire manual very carefully before use. Any damage or injury resulting from misuse or incorrect 
handling is the sole responsibility of the owner and/or operator. 

This symbol 

marks warnings and cautions in this operation manual.  Carefully follow them for your own safety 

and the safety of others. 

 

Warning! 

1.  Use only in a well-ventilated area.   
2.  Do not operate in an area where contaminants can be drawn into the compressor. 
3.  Do not operate in extremely dusty or marine environments.   
4.  Do not operate near smoke or an open flame. 
5.  This compressor generates pressurized air, heat, and noise.  Eye, skin, and ear protection 

are recommended during use. 

6.  The compressor should not be disassembled for any reason, otherwise serious damage/

injury/death may be caused to you or others.  

7.  Disassembly of this compressor can result in leaks, damage, and will void your warranty. 
8.  Do not transport or place this compressor into a storage location while it is pressurized or 

is hot after running.  Depressurize and allow to cool before storing or transporting. 

9.  Use only approved filters, hoses, fittings, and accessories.  It is your responsibility to check 

for leaks before using to fill (see instructions later in this manual). 

10.  This compressor is designed to produce compressed air only.  Do not attempt to feed other 

gasses or pressurized air through for compression. NO OTHER GAS OR GAS COMBINATION 
CAN BE USED. 

11.  Failure to follow instructions and heed warnings may result in damage, serious injury, and/

or death. 

 

This compressor has a maximum operating pressure of 

4500 PSI (310 BAR)

 and a maximum operating 

temperature of 

195 Degrees Fahrenheit

.  Do not allow the machine to operate above these conditions.  

*

Allow the compressor to cool back to ambient temperature after each fill cycle.

*

 

 

WHAT’S IN THE BOX?

 

 

  • 

Hatsan Volt Dual-Power Portable PCP Compressor 

  • 

Power Connection Cables 

  • 

Fill Whip w/ Inline Moisture Filter 

  • 

Test Plug 

  • 

Spare Filter Media 

  • 

Spare Seal Kit 

  • 

Operation Manual 

Summary of Contents for TactAir Volt

Page 1: ...Hatsan TactAir Volt Dual Power Portable Compressor Operation Manual REV1 3 2020...

Page 2: ...2...

Page 3: ...thers 7 Disassembly of this compressor can result in leaks damage and will void your warranty 8 Do not transport or place this compressor into a storage location while it is pressurized or is hot afte...

Page 4: ...or any reason Use caution when purging air from the system Loosen the vent screw slowly The escaping air can cause damage Noise from purging may be loud especially if you are in a small space Hearing...

Page 5: ...e in addition to any other existing loads WARNING DO NOT OPERATE THIS COMPRESSOR IF THE SYSTEM VOLTAGE IS BELOW 12V Power Source Power Source Connection Fuse Size 12 14V DC Alligator Clamp to Yellow C...

Page 6: ...illuminate and show system voltage Operating voltage is 12 14V 4 FIRST RUN LEAK TEST Follow the steps below prior to using the compressor to fill any reservoir before use after storage or any time you...

Page 7: ...ipped to verify the pressure does not exceed that of the operating pressure of the device 7 The compressor will stop running once it has reached the set pressure and display a message confirming that...

Page 8: ...to allow the compressor to cool before handling or moving after it has been used Leak Checks Perform a System Leak Test every 30 hours of runtime or every six months whichever occurs first o Additiona...

Page 9: ...nnected Insert test plug into fill whip or connect whip to reservoir System takes a long time to fill or build pressure Bleed valve is open or partially open Close bleed valve by turning the screw clo...

Page 10: ...r Return shipping of the repaired or replaced product back to the consumer What Is NOT Covered Repairs required due to abuse misuse neglect or failure to perform proper maintenance Damages resulting f...

Page 11: ...11...

Page 12: ...12 www HatsanUSA com facebook com HatsanUSA instagram com hatsan_usa youtube com c HatsanUSAInc HatsanUSA Inc PO Box 576 Bentonville AR 72712 P 479 273 5629 F 918 517 3040...

Reviews: