background image

 

BEFORE YOU BEGIN 

 

CAUTION 

• 

This compressor is not intended to produce breathable air. 

• 

This portable compressor is not intended to fill volumes above 1000cc (1L)  at 
a time or pressures above 310 BAR (4500 PSI).  Runtimes should be limited to 
30-minute intervals. 

• 

To reliably produce clean air, the filter media must be monitored on a regular 
basis and changed when necessary.  Filter life will vary due to many factors, 
including but not limited to: humidity, temperature, purge frequency, and cycle 
times. 

• 

Wear safety glasses when operating this equipment. 

• 

Always monitor the compressor while it is running.  Never let it run above its 
maximum operating pressure or temperature. 

• 

DO NOT leave this compressor running while unattended, and NEVER allow it to 
operate above 310 BAR / 4500 PSI for any reason. 

• 

Use caution when purging air from the system.  Loosen the vent screw slowly.  
The escaping air can cause damage. 

• 

Noise from purging may be loud, especially if you are in a small space.  Hearing 
protection is recommended while the compressor is operating. 

• 

When filling a reservoir, it can become very warm to the touch.  Refrain from 
holding the airgun or reservoir during the filling process. 

• 

Parts of this compressor can become hot enough to cause burns.  Do not 
operate the compressor without all its protective panels in place, and do not 
touch the ventilation openings or handle the compressor at any time during or 
immediately after operation.  It is advisable to allow the compressor to cool 
back to ambient temperature before handling or moving after it has been used. 

 
 

SECTION INDEX 

 

 
1.  Power Requirements 
2.  Parts of Your Compressor 
3.  Initial Setup Instructions 
4.  First Run & Leak Test 
5.  Compressor Fill Operation 
6.  Maintenance 
7.  Troubleshooting 
8.  Warranty and Service 

Summary of Contents for TactAir Volt

Page 1: ...Hatsan TactAir Volt Dual Power Portable Compressor Operation Manual REV1 3 2020...

Page 2: ...2...

Page 3: ...thers 7 Disassembly of this compressor can result in leaks damage and will void your warranty 8 Do not transport or place this compressor into a storage location while it is pressurized or is hot afte...

Page 4: ...or any reason Use caution when purging air from the system Loosen the vent screw slowly The escaping air can cause damage Noise from purging may be loud especially if you are in a small space Hearing...

Page 5: ...e in addition to any other existing loads WARNING DO NOT OPERATE THIS COMPRESSOR IF THE SYSTEM VOLTAGE IS BELOW 12V Power Source Power Source Connection Fuse Size 12 14V DC Alligator Clamp to Yellow C...

Page 6: ...illuminate and show system voltage Operating voltage is 12 14V 4 FIRST RUN LEAK TEST Follow the steps below prior to using the compressor to fill any reservoir before use after storage or any time you...

Page 7: ...ipped to verify the pressure does not exceed that of the operating pressure of the device 7 The compressor will stop running once it has reached the set pressure and display a message confirming that...

Page 8: ...to allow the compressor to cool before handling or moving after it has been used Leak Checks Perform a System Leak Test every 30 hours of runtime or every six months whichever occurs first o Additiona...

Page 9: ...nnected Insert test plug into fill whip or connect whip to reservoir System takes a long time to fill or build pressure Bleed valve is open or partially open Close bleed valve by turning the screw clo...

Page 10: ...r Return shipping of the repaired or replaced product back to the consumer What Is NOT Covered Repairs required due to abuse misuse neglect or failure to perform proper maintenance Damages resulting f...

Page 11: ...11...

Page 12: ...12 www HatsanUSA com facebook com HatsanUSA instagram com hatsan_usa youtube com c HatsanUSAInc HatsanUSA Inc PO Box 576 Bentonville AR 72712 P 479 273 5629 F 918 517 3040...

Reviews: