background image

 

7.  Troubleshooting 

Problem 

Possible Cause(s) 

Solution(s) 

Digital display does not 

turn on 

 

No power to compressor 

Verify power source has enough 

voltage/amperage to power the 

system. 

Supply fuse is blown 

Replace the fuse. 

Incorrect AC Voltage Selection 

Verify the AC voltage selector 

position matches the input voltage. 

Compressor motor does 

not start 

 

No power to compressor 

Verify power source has enough 

voltage/amperage to power the 

system. 

Supply fuse is blown 

Replace the fuse. 

Pressurized system 

Release pressure by opening the 

bleed valve until system is 

depressurized. 

System does not build 

pressure 

 

Bleed valve is open 

Close bleed valve by turning the 

screw clockwise until is it hand tight. 

Fill whip is not connected 

Insert test plug into fill whip or 

connect whip to reservoir. 

System takes a long time 

to fill or build pressure 

 

Bleed valve is open or partially 

open 

Close bleed valve by turning the 

screw clockwise until is it hand tight. 

Leak in system 

Perform System Leak Test to locate 

the leak. 

Operating temperature too 

high

 

Poor air circulation 

Make sure system fans have 

adequate airflow and are not 

blocked. 

Compressor overheating 

Stop and allow the compressor to 

cool before continuing. 

Fan not running 

Make sure system fan is turning.  

Contact HatsanUSA for repairs if it 

does not turn on. 

Temperature gauge does 

not read

 

Batteries are bad 

Replace the 2 AG13/LR44 Batteries 

in the temperature gauge. 

If you experience a problem that is not covered by this troubleshooting guide, or if you continue 
to have the same problem, discontinue use and contact HatsanUSA (

Service@HatsanUSA.com 

or 

(877)-278-4448 x201

) for assistance. 

Summary of Contents for TactAir Volt

Page 1: ...Hatsan TactAir Volt Dual Power Portable Compressor Operation Manual REV1 3 2020...

Page 2: ...2...

Page 3: ...thers 7 Disassembly of this compressor can result in leaks damage and will void your warranty 8 Do not transport or place this compressor into a storage location while it is pressurized or is hot afte...

Page 4: ...or any reason Use caution when purging air from the system Loosen the vent screw slowly The escaping air can cause damage Noise from purging may be loud especially if you are in a small space Hearing...

Page 5: ...e in addition to any other existing loads WARNING DO NOT OPERATE THIS COMPRESSOR IF THE SYSTEM VOLTAGE IS BELOW 12V Power Source Power Source Connection Fuse Size 12 14V DC Alligator Clamp to Yellow C...

Page 6: ...illuminate and show system voltage Operating voltage is 12 14V 4 FIRST RUN LEAK TEST Follow the steps below prior to using the compressor to fill any reservoir before use after storage or any time you...

Page 7: ...ipped to verify the pressure does not exceed that of the operating pressure of the device 7 The compressor will stop running once it has reached the set pressure and display a message confirming that...

Page 8: ...to allow the compressor to cool before handling or moving after it has been used Leak Checks Perform a System Leak Test every 30 hours of runtime or every six months whichever occurs first o Additiona...

Page 9: ...nnected Insert test plug into fill whip or connect whip to reservoir System takes a long time to fill or build pressure Bleed valve is open or partially open Close bleed valve by turning the screw clo...

Page 10: ...r Return shipping of the repaired or replaced product back to the consumer What Is NOT Covered Repairs required due to abuse misuse neglect or failure to perform proper maintenance Damages resulting f...

Page 11: ...11...

Page 12: ...12 www HatsanUSA com facebook com HatsanUSA instagram com hatsan_usa youtube com c HatsanUSAInc HatsanUSA Inc PO Box 576 Bentonville AR 72712 P 479 273 5629 F 918 517 3040...

Reviews: