2-4L41C, 2-4M41(Z), 4L42C, 4M42
Operation and use
HATZ
51
Manual
NOTICE
i
▪
If the engine stops again immediately after starting, or stops
independently during operation, this is an indication that a
monitoring element of the automatic shutoff has activated.
▪
Remedy the fault before making further starting attempts
(see chapter
▪
The automatic shutoff is
no
protection against low oil level.
This means that the oil level must be checked every 8 - 15
operating hours despite the automatic shutoff. (see section
7.9 Check the oil level, page 57
Procedure when faults occur
Step
Activity
1
Check the indicators (5-7).
After the engine comes to a standstill, the fault will continue to
be displayed by the indicator for approx. another 2 minutes.
2
Then the electrical equipment switches off automatically.
3
Set the starting key to position "0".
4
Turn the starting key back to position "I".
The fault display lights up again.
Remedy the fault before making further starting attempts (see
chapter
).
The indicator then goes out at the next start.
Model with exhaust gas return valve
The engines
4L42C
and
4M42
are equipped with an exhaust gas return
valve (EGR). The indicators change as follows:
5
Indicator EGR
Summary of Contents for 2-4L41C
Page 2: ......