2-4L41C, 2-4M41(Z), 4L42C, 4M42
Maintenance
HATZ
65
Manual
NOTICE
i
In case of heavy contamination, shorten the maintenance inter-
vals accordingly (see chapter
8.2.2 Maintenance plan, page 62
).
Overview
2-4M41 and 4M42
3
2-4L41C and 4L42C
1
Intake opening for combustion air
2
Dust outlet opening
3
Cyclone (option)
Procedure
Step
Activity
1
Check the intake opening (1) for coarse contamination such as
leaves, heavy dust deposits, etc., and clean if necessary.
2
Check that the dust outlet opening (2) at the bottom of the cy-
clone precleaner is clear.
3
If the dirt contamination is oily, remover the cyclone (3) and
clean it.
Summary of Contents for 2-4L41C