Transport inspection
Inspect the delivery immediately on receipt for completeness and transport
damage. In the event of transport damage being visible from the outside, proceed
as follows:
•
Do not accept the delivery or only do so subject to reservations.
•
Make a note of the extent of damage in the transport documentation or
delivery note provided by the transporter.
•
Submit a claim for every defect as soon as it has been identifi ed.
•
Make a note of the extent of damage in the transport documentation or
delivery note provided by the transporter.
Scope of delivery
The universal sleeve caps for smooth and corrugated pipes DA75-90,
MS78 U1/24-52 – Universal sleeve cap, water/electricity
MS78 EW 1/24-40 + 3/7-14 – Sleeve cap for electricity/water
MS78 KD 1/13-21 + 3/7-13 + 1/5-13 – Sleeve cap for communication
MS78 D/0 – Sleeve cap for blind sealing
MS78 z/d – Sleeve cap with individual assignment
are supplied with the following:
1 sleeve cap incl. blind plug
2 stainless steel tension straps
The universal sealing elements,
PolySafe Wasser WD 1/32/40/50 (universal sealing element for water)
PolySafe Elektro ED 1/20-34 (universal sealing element for electricity)
PolySafe Elektro ED 1/26-29, 36-39, 43-46, 48-51 (universal sealing ele-
ment for electricity)
PolySafe Elektro/Kommunikation ED/KD 1/26-30 + 3/5-8 + 2/7-13 (univer-
sal sealing element for electricity and communication)
PolySafe Kommunikation KD 1/13-21 + 3/7-13 + 1/5-13 (universal sealing
element for communication)
PolySafe D 0 (blind sealing element for blind sealing)
PolySafe S z/d (sealing element with individual assignment)
are supplied with the following:
1 sealing element incl. blind plug
1 tab
The matching screws for the PolySafe sealing elements are included with all
single and multi-utility building entries.
Storage
NOTE!
Damage due to improper storage!
Signifi cant damage can occur in the event of improper storage.
•
Protect the universal sealing elements and sleeve caps from damage, damp
and soiling prior to installation. Only intact components may be installed.
•
The universal sealing elements and sleeve caps must be stored in such a way
that it is not exposed to low temperatures (<5° C), high temperatures (>30°
C) or direct sunlight.
Disposal
If no return or disposal agreement has been concluded, recycle dismantled components
after they have been properly dismantled:
•
Metal remains are to be scrapped according to existing environmental regulations.
•
Dispose of elastomer segments according to existing environmental regulations.
•
Dispose of plastics according to existing environmental regulations.
•
Dispose of packaging material according to existing environmental regulations.
Instructions de sécurité et informations
Public
Ce montage peut être effectué uniquement par des personnes compétentes.
Les personnes qualifi ées et formées pour le montage
•
ont connaissance des règles de sécurité et de prévention actuellement en vigueur,
•
savent utiliser un équipement de sécurité,
•
savent manier des outils manuels et électriques,
•
ont connaissance des normes et directives actuellement en vigueur pour la pose
de tuyaux/câbles et pour le remplissage de tranchées,
•
ont connaissance de la règlementation et des consignes actuellement en vigueur
des entreprises de fourniture en énergie,
•
ont connaissance des prescriptions d'utilisation du béton étanche de WU et des
normes relatives à l'étanchéité d'ouvrages actuellement en vigueur.
Informations générales et utilisation prévue
Conformément à l‘usage prévu, nos produits sont conçus exclusivement pour être
FR
Safety instructions and informations
Target group
The installation may only be carried out by technical experts.
Qualifi ed and trained individuals carrying out installation must have
•
knowledge of general safety and accident prevention regulations as amended,
•
knowledge of how to use safety equipment,
•
knowledge of how to use hand tools and electric tools,
•
knowledge of the relevant standards and guidelines for laying pipes/cables and
for backfi lling utility trenches, as amended,
•
knowledge of the regulations and installation guidelines of the supply company
as amended,
•
knowledge of the impermeable concrete directive and building waterproofi ng
standards as amended.
General information and intended use
According to their intended use, our products have been designed exclusively for
installation in buildings made from state-of-the-art construction materials. We do
not accept liability for use deviating from or beyond this unless our express written
confi rmation has been obtained in advance.
For warranty conditions, please see our current General Terms and Delivery Conditions.
The
sleeve caps
are designed to ensure reliable sealing of the sleeve pipe to
electric cables, water pipes, telecommunication lines and district heating cables.
The
universal sealing elements
are suitable for all utility types – electricity,
water and telecommunications.
Safety
This section provides an overview of all the main safety aspects for optimum protec-
tion of personnel and a safe installation process. If there is a failure to observe the
instructions and safety information set out here, this may result in signifi cant hazards.
The sealing elements or sleeve caps installation must comply with the relevant profes-
sional association regulations, VDE provisions, national safety and accident prevention
regulations as well as company regulations (work and procedural instructions).
The fi tter must wear the relevant protective clothing.
Only intact components may be installed.
The following instructions are to be observed prior to installa-
tion of PolySafe sealing elements and sleeve caps:
WARNING!
Risk of injury in the event of improper installation!
Improper installation can result in signifi cant bodily harm and property damage.
•
The nationally applicable laying and fi lling regulations for pipes and cables are
to be observed at all times.
•
Seal the underground and cable substructure well prior to laying pipes/cables so
that the latter cannot subside.
NOTE!
No sealing due to incorrect assembly!
Improper installation can result in damage.
•
In the case of thin-walled or foamed pipes, only tighten the tension straps of
the sleeve caps up to a point at which the pipes are not deformed.
•
The norms and directives referred to here are valid in Germany only. In all other
countries, the national norms and directives are to be observed as amended.
•
No cleaning agents containing solvent may be used to clean the cable seal. We
recommend using cable cleaner KR M.T.X.
•
For details of other accessories and further information, see
www.hauff-technik.
de
and the technical specifi cation sheets.
Personnel requirements
Qualifi cations
WARNING!
Risk of injury in case of inadequate qualifi cation!
Improper handling can result in signifi cant bodily harm and damage to property.
•
Installation may only be carried out by qualifi ed and trained individuals who
have read and understood these instructions.
Skilled experts
Based on their specialist training, skills, experience and familiarity with the relevant
provisions, standards and regulations, skilled experts are able to carry out the
worked assigned, independently identifying and avoiding potential hazards.
Transport, packaging, scope of delivery and storage
Safety instructions in connection with transport
NOTE!
Damage in the event of improper transport!
Signifi cant damage can occur in the event of improper transport.
•
When unloading packaging items on delivery and in the course of in-house
transport, proceed with care and observe the symbols on the packaging.