background image

8    Technical data 

 

18 

 

 

8

 

Technical data 

8.1

 

Key figures and specifications 

Reference temperature 23 °C 

HS connections 

High voltage 

6.7 ±1 kV~ 

Short-circuit current 

I

k

 

 5 mA 

 

 

Square wave signal: Pulse width 

Tp/To 

Cycle in > 40 % 

Cycle out < 1 % 

Amplitude 

10 V~ ±20 % 

Frequency 

1 kHz ±20 % 

Polarity 

Positive 

 

 

8.2

 

Supply voltage 

Unit type 

Rated value 

Frequency 
range 

Power 
consumption 

01.7913.055 

100 V~ 

±

10 % 

50 - 60 Hz 

P

max

 = 80 VA 

01.7913.005 

115 V~ 

±

10 % 

50 - 60 Hz 

P

max

 = 80 VA 

01.7912.005 

230 V~ 

±

10 % 

50 - 60 Hz 

P

max

 = 80 VA 

 

 

 

 

Summary of Contents for 01.7912.005

Page 1: ...Static Line Operating instructions Discharging power pack EN 8 SLC MT Ident number 01 7913 055 100 V 01 7913 005 200 V 01 7912 005 230 V Keep for future use GB...

Page 2: ......

Page 3: ...Product overview 8 4 Install 9 5 Operate 13 5 1 Normal operation 13 5 2 Cyclic operation 13 6 Troubleshooting 14 6 1 Replacing fuse 15 6 2 Flow chart 16 7 Accessories spare parts 17 8 Technical data...

Page 4: ...eviated HV in these operating instructions e g HV terminal The illustrations in this document are a simplified representation of the product They render only the technical facts and provide support fo...

Page 5: ...ose of with household garbage Caution danger spot warning 1 2 Symbols on the discharging power pack WARNING High voltage ATTENTION Only plug in unplug the ionizing unit at the HV terminal when the dis...

Page 6: ...In the event of visible damage or suspected electrical defects take the discharging power pack out of operation immediately and secure against inadvertent reuse Protect the discharging power pack from...

Page 7: ...tmospheres The discharging power pack is intended exclusively for the supply of alternating high voltage to HAUG ionizing units with X 2000 connector In combination with an ionizing unit electrostatic...

Page 8: ...switch is lit green if the discharging power pack is switched on B Indicator light C Fuse holder with fuse Replacing fuse refer page 15 D 2 x HV connection E Signalling socket with jumper plug F Eart...

Page 9: ...us overloading of the discharging power pack may result in failures Never exceed the permissible connected length Never install the discharging power pack on a surface generating or radiating heat Nev...

Page 10: ...fect its function We recommend attaching the discharging power pack with the HV connections facing downwards protection against moisture oil and dirt 4 Make sure that the discharging power pack is swi...

Page 11: ...witched on spark overs will occur at the HV connection This may result in defects in the discharging power pack Switch off discharging power pack before plugging in unplugging ionizing unit 7 Connect...

Page 12: ...e Pin 2 0 V Pin 3 not used Pin 4 not used Pin 5 Clock switch connection Pin 6 Clock switch connection PE Shield Ground signal ground NOTE The discharging power pack only supplies voltage if the signal...

Page 13: ...eration fails the indicator light turns off In order to correct the malfunction proceed with troubleshooting the error Refer page 14 5 2 Cyclic operation The signal line K6 is connected to the K6 sign...

Page 14: ...is provided on the back of the envelope Fault Cause Troubleshooting Mains switch does not illuminate Mains failure Check mains fuse Defective fuse in discharging power pack Check fuse in discharging...

Page 15: ...es Never bridge the fuse The unit type and the rated voltage are indicated on the nameplate 1 Disconnect the discharging power pack 2 Determine and rectify the reason for the fuse failure 3 Use a scre...

Page 16: ...g socket Switch on the discharging power pack yes Switch off discharging power pack and connecting a ionizing unit Switch on the discharging power pack This ionizing unit has a fault Short circuit Ion...

Page 17: ...e authorized local sales agent of Mettler Toledo Article Order number Point electrode 11107765 Optional second electrode 11107762 U Electrode universal 11107764 U Electrode small 11140161 Ionizing kit...

Page 18: ...rt circuit current Ik 5 mA Square wave signal Pulse width Tp To Cycle in 40 Cycle out 1 Amplitude 10 V 20 Frequency 1 kHz 20 Polarity Positive 8 2 Supply voltage Unit type Rated value Frequency range...

Page 19: ...e mean seal level to 2000 m Temperature Rated application range 5 to 45 C Limit range for storage and transport 15 to 60 C Relative humidity Rated application range A RF B C Air pressure Rated applica...

Page 20: ...data 20 8 4 Housing Protection type IP 20 Protection class I Excess power category II Degree of pollution 2 Mains connection via the IEC power cable Dimensions Height 245 mm Width 128 mm Depth 125 mm...

Page 21: ...ct the signalling line from the discharging power pack 5 Remove the discharging power pack from the production process 9 1 Storing Always store our products in a dry and cool place 9 2 Disposing Never...

Page 22: ......

Page 23: ......

Page 24: ...EN 8 SLC MT v09gb docx V09 22 01 2019 D 0273 GB made by...

Reviews: