Operation
Page 6
HAUG
Static Meter
Ι
3
Operation
Press the "function/on"-key to switch the unit on. Press the "function/on"-key
twice in short intervals to switch the unit off.
The unit will switch off automatically when the "function/on"-key was not used
for 5 minutes.
3.1
Hold
The unit has a hold-function keeping the measured value stored on the
display . Press the "function/on"-key once shortly to activate the hold function
- "hold" will appear then in the first row of the display, while the stored value is
shown in the second row. To exit the hold-function, press the "function/on"-
key once again shortly and the actual measurement value will appear on the
display.
3.2
Measurement ranges
The measurement distance of 2 cm is always indicated after each switch-on.
If this distance is used, the unit has to be positioned at the distance of 2 cm
monitoring the object. This distance is ideal in most cases, as voltage levels
up to 20 kV can be measured (please see Technical Data).
The measurement distance should be increased, if the measurement object is
highly charged or when the object has a rough surface. The lowest
measurement distance of 1 cm should be selected, where low charges are
present and the surface of the object has a smooth surface.