Operating instructions angular electrode and U-shaped electrode
Winkel- und U-Elektroden v02gb
Page 5
2.3
Operator qualifications
The unit may be installed and put into operation by trained electricians only or by authorized and
persons informed about the potential dangers. The above mentioned persons must have read the
operating instructions and must follow the instructions, notes and safety advice.
3
Installation
The unit may be installed by trained electricians only and by authorized persons informed about
the potential dangers. The above mentioned persons must have read the operating instructions
and must follow the instructions, notes and safety advice.
3.1
Important installation instructions
The operation of the unit is not affected by the position in which it is installed.
Do not connect the units to the power
pack until installation is completed.
Switch off the power pack before connecting
or disconnecting the coaxial connectors!
3.2
Ionizing units
The numerals refer to the illustration at the end of these instructions.
-
Example for ionizers.
Most favourable distance ionizing unit - material
approx. 20 - 30 mm, min. 10 mm, max. 80 mm.
Distance B to grounded machine part always greater than distance A.
Install ionizer so that no machine parts are located behind the material.
Never attach metal holders above the ionizing needles.
Install high-voltage cables without kinks. Smallest bending radius 50 mm.
-
Examples of holders.