HAULOTTE GROUP
1 SAFETY
14
MAINTENANCE (CONTINUED)
Battery Maintenance
Ensure the following general safety precautions are followed when performing battery maintenance
on the aerial work platform:
ALWAYS
check the battery fluid level daily.
ALWAYS
wear safety glasses when working with or near batteries.
ALWAYS
avoid contact with battery acid. Battery acid causes serious burns and should be kept
away from skin or eyes. If contact occurs, flush with water and consult a physician immediately.
ALWAYS
disconnect ground cable first when removing battery.
ALWAYS
connect ground cable last when installing battery.
ALWAYS
charge batteries in open, well-ventilated areas.
ALWAYS
replace batteries using only parts recommended by manufacturer / factory.
ALWAYS
use
only batteries with sealed caps over cells.
NEVER
smoke while servicing batteries.
NEVER
charge batteries near flammable materials.
NEVER
allow batteries to overcharge and boil.
NEVER
short across battery posts to check for current.
NEVER
break a live circuit at the battery.
NEVER
disconnect battery from charger while charger is connected to a live power source.
NEVER
jump-start other vehicles using the aerial work platform batteries.
Summary of Contents for 3522A
Page 1: ...OPERATOR S MAINTENANCE MANUAL B33 01 0093 Rev 4 May 2013...
Page 76: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 76 DECAL KIT ANSI...
Page 78: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 78 IDENTIFICATION PLATES OPTIONAL EQUIPMENT ANSI...
Page 84: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 84 DECAL KIT CE...
Page 86: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 86 IDENTIFICATION PLATES OPTIONAL EQUIPMENT CE...
Page 88: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 88 DECAL KIT AU...
Page 90: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 90 IDENTIFICATION PLATES OPTIONAL EQUIPMENT AU...
Page 92: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 92...
Page 106: ...HAULOTTE GROUP 8 MATERIAL SAFETY 106 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL...