GROUND (LOWER) CONTROL PANEL (CONTINUED)
Figure 3-1. Ground (Lower) Control Panel
20. Auto
Level
LED
When this LED is “FLASHING” it indicates that the booms are not in the “stowed” position,
and the outriggers cannot be operated (non-functional). When this LED is “ON SOLID” it
indicates that the booms are in the “stowed” position, and the outriggers can be operated
(functional).
21-24. Outrigger
Controls
For simultaneous automatic outrigger extension / retraction of all four (4) outriggers: Select
the
EXTEND
(21)
button or
RETRACT
(22)
button and the
AUTO LEVEL
(23)
button at the same
time. To individually extend or retract the outriggers: Select the
EXTEND
(21)
button or
RETRACT
(22)
button, and one of the four
OUTRIGGER
(24)
buttons at the same time. The
outrigger indicator LEDs
(20)
lights up when the outriggers are properly deployed and the
aerial work platform weight is on the outrigger foot pads. Each of the outer outrigger LEDs
(25)
indicates load is on the outrigger foot pad. Each of the inner outrigger LEDs
(26)
, when
flashing, indicate that side is low, and needs to be further raised for leveling.
Summary of Contents for 3522A
Page 1: ...OPERATOR S MAINTENANCE MANUAL B33 01 0093 Rev 4 May 2013...
Page 76: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 76 DECAL KIT ANSI...
Page 78: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 78 IDENTIFICATION PLATES OPTIONAL EQUIPMENT ANSI...
Page 84: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 84 DECAL KIT CE...
Page 86: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 86 IDENTIFICATION PLATES OPTIONAL EQUIPMENT CE...
Page 88: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 88 DECAL KIT AU...
Page 90: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 90 IDENTIFICATION PLATES OPTIONAL EQUIPMENT AU...
Page 92: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 92...
Page 106: ...HAULOTTE GROUP 8 MATERIAL SAFETY 106 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL...