114
24203 3237 0
E 06 10
EN
F
- Special procedure
Engine-powered articulated lifts, 12 - 26 m
8 - Gas bottle removal
9 - On-board generator(Option)
9.1 - PRINCIPLE
The on-board generator supplies voltage ( 220 V or 110 V depending on the option) in the
cage (or platform) able to connect a tool with the maximum power of 3 kW (4 Hp) .
9.2 - PROCEDURE
Make sure that there are no open flames or incandescent sources close to the machine.
1.
Make sure that the emergency stop button on the
ground control box has been pressed.
2.
Close the gas bottle valve( 1 ).
3.
Set the fuel selector ( 23 ) to petrol.
4.
Loosen the coupling ( 2 ) by hand.
5.
Remove the pipe ( 3 ) from the valve.
6.
Open the lanyards to remove the gas bottle.
Do not expose the on-board generator to direct contact with a water beam or a high pressure cleaner.
Put into service :
1.
Start the machine. Heat the engine during 15 mn befo-
re any operation.
2.
Set the switch selector, above the socket power, to
ON 1. The green indicator comes on indicating the on-
board generator start-up.
3.
Connect the tool to the socket.
4.
You can change the tool at any time.
N.B.-:-W
HEN
USING
THE
ON
-
BOARD
GENERATOR
,
YOU
CANNOT
MAKE
ANY
MACHINE
MOVEMENTS
. T
O
MAKE
A
MOVEMENT
,
YOU
MUST
SWITCH
OFF
THE
ON
-
BOARD
GENERATOR
.
Power off :
5.
Disconnect the tool from the socket.
6.
Set the switch selector, above the socket power, to
OFF. The green indicator extinguish.
7.
Machine movements are once again active.
1
2
3
1