24203 3237 0
E 06 10
EN
C
- Machine layout
Engine-powered articulated lifts, 12 - 26 m
2
Engine oil pressure indicator
Low engine oil pressure
1
3
Engine temperature indicator
High engine oil temperature
4
Battery charge indicator
Low battery charge
5
Air filter clogging indicator
Clogged air filter
6
Platform overload indicator
Platform overload
7
Radius limitation indicator
Close to radius limitation :
• The indicator flashes
• Movement is slowed down
Radius limitation reached :
• The indicator flashes continuously
• An automatic movement is performed to return to the
authorized radius limitation
8
Jib lifting / lowering selector
Move upwards : Jib lifting
Move downwards : Jib lowering
9
Boom telescoping selector
Move to the left : Telescope extension
Move to the right : Telescope retraction
10
Boom raising selector
Move upwards : Boom raising
Move downwards : Boom lowering
12
Arm lifting selector
Move upwards : Arm lifting
Move downwards : Arm lowering
13
Platform compensation or transport
position selector
Move to the right : Platform compensation lowered or
placed in transport position
Move to the left : Platform compensation lifted or placed in
operating position
14
Turntable rotation selector
Move to the left : Counter clockwise (CCW) rotation
Move to the right : Clockwise rotation
15
Emergency stop button
Pulled out (activated) : Ground control box switched on
Pushed down (deactivated) : De-energizes control system
19
Back-up unit selector
Press in and hold : Back-up unit activated
Release : Back-up unit deactivated
20
Hour meter
Total machine running hours
21
Engine acceleration selector
Move to the right : Engine speed acceleration
Move to the left : Engine speed when idle
22
Engine start-up selector
Engine start-up
23
Petrol/Gas selector
2
LPG : Gas supply
G : Petrol supply
24
Beacon light selector
Move upwards : Beacon light activated
Move downwards : Beacon light deactivation
72
Control box activation key selector
Left : Platform control box activated
Center : De-energizes control system
Right : Ground control box activated
167
Engine temperature indicator
3
High coolant temperature
228
'Enable Switch' selector / Back-up unit
selector
4
Move upwards : Movement validation
Move downwards : Back-up unit activatedMovement
validation
1. Perform the required maintenance (see the machine maintenance book)
2. For equipped machines
3. For equipped machines
4. For equipped machines
Marking
Description
Function