70
4000599070
E11.16
USA / GB
Control-Filling-up-Battery charge
Battery
E018
10 min
5 - Battery charge
Battery discharged :
• Never discharge the batteries to more than 80 % of their capacity in 5 h (hours).
• Never leave the batteries discharged.
• Do not put off recharging the batteries in cold weather as the electrolyte may freeze.
Battery to be charged :
• When should the batteries be charged ?
• When the batteries are discharged to between 35 % and 80 % of their nominal capacity.
• After a long period of non-use.
• How to charge the batteries ?
• Ensure that the mains supply is compatible to the charger's consumption.
• Top up the batteries with distilled water to the minimum electrolyte level if any of the elements are below this
minimum level.
• Work in a clean and well-ventilated area away from naked flames.
• Open the bay.
• Use the machine's on-board charger. The charger has a charge rate compatible to the battery capacity.
• During charging :
• The machine's electric system is automatically deactivated while the external power supply is connected to
the machine.
• Ensure that the battery are at a temperature not exceeding 45 °C(113 °F) (be careful in summer or in places
with a high ambient temperature).
• Do not remove or open the caps on the elements.
• After charging :
• Top up the electrolyte level, if necessary.
• Avoid overflowing.
• Wash the top of the batteries without removing the caps.
• Dry with compressed air or clean cloths.
• Oil the terminals.
Summary of Contents for HA120PX
Page 1: ...Maintenance book HA120PX 4000599070 E11 16 USA GB Maintenance book HA120PX ...
Page 2: ...2 4000599070 E11 16 USA GB HA120PX ...
Page 14: ...14 4000599070 E11 16 USA GB HA120PX A Safety precautions Notes ...
Page 50: ...50 4000599070 E11 16 USA GB HA120PX C Maintenance Notes ...
Page 52: ...52 4000599070 E11 16 USA GB Control Oil change Wheel reducer E002 15 mn Notes ...
Page 54: ...54 4000599070 E11 16 USA GB Replacement Hydraulic filter cartridge E003 15 min Notes ...
Page 56: ...56 4000599070 E11 16 USA GB Filling up Oil change Fuel tank E004 15 mn Notes ...
Page 64: ...64 4000599070 E11 16 USA GB Replacement Tightening Wheel E006 15 min Notes ...
Page 66: ...66 4000599070 E11 16 USA GB Tightening Screws bolts and nuts E007 15 min Notes ...
Page 72: ...72 4000599070 E11 16 USA GB Control Filling up Battery charge Battery E018 10 min Notes ...
Page 74: ...74 4000599070 E11 16 USA GB Changing glow plugs Glow plugs E030 30 mn Notes ...
Page 78: ...78 4000599070 E11 16 USA GB HA120PX D Diagnosis assistance Notes ...
Page 90: ...90 4000599070 E11 16 USA GB HA120PX E Electric circuit Notes ...
Page 100: ...100 4000599070 E11 16 USA GB HA120PX F Hydraulic circuit Proportional unit Diagram extract ...
Page 107: ...1 4000599070_USA_GB_e11 16 Electrical diagram HA120PX 1 HA120PX 1 1 FOLIO 1 7 ...
Page 108: ...2 Electrical diagram HA120PX 1 2 FOLIO 2 7 ...
Page 109: ...3 Electrical diagram HA120PX 1 3 FOLIO 3 7 ...
Page 110: ...4 Electrical diagram HA120PX 1 4 FOLIO 4 7 ...
Page 111: ...5 Electrical diagram HA120PX 1 5 FOLIO 5 7 ...
Page 112: ...6 Electrical diagram HA120PX 1 6 FOLIO 6 7 ...
Page 113: ...7 Electrical diagram HA120PX 1 7 FOLIO 7 7 ...
Page 114: ...8 Electrical diagram HA120PX ...
Page 116: ...2 HYDRAULIC DIAGRAM HA120PX ...