46
4000599070
E11.16
USA / GB
HA120PX
C
- Maintenance
7.3.3 - Hydraulics
7.3.3.1 - Oil replacement
Replace oil after each major intervention, and each time an anomaly has been detected.
Take an oil sample each year, check the viscosity, ensure there are no foreign bodies and
change if necessary. Systematically change the oil in the hydraulic circuit every 2 years.
• Only use oils that that match the technical characteristics that correspond to HAULOTTE®
recommendations (
Section B 1 - Lubrication diagram - List of ingredients) or
contact HAULOTTE Services®.
• Do not mix two oils with different characteristics : If necessary, drain and clean the whole system.
• Check the cleanliness of the oil filter cartridge (no metal shavings, rubber, plastic, …) : If necessary,
drain and clean the whole system.
• Respect the following step during filling :
• The machine must be completely stowed (For machines fitted with : Stabilisers raised).
• Fill the tank.
• 1 : Perform a complete cycle (fully extend and retract) of each cylinder.
• 2 : Fill the tank if necessary(Never above of the maximum level).
• Repeat the step ( 1 ) and ( 2 ) for each cylinder on the machine.
Summary of Contents for HA120PX
Page 1: ...Maintenance book HA120PX 4000599070 E11 16 USA GB Maintenance book HA120PX ...
Page 2: ...2 4000599070 E11 16 USA GB HA120PX ...
Page 14: ...14 4000599070 E11 16 USA GB HA120PX A Safety precautions Notes ...
Page 50: ...50 4000599070 E11 16 USA GB HA120PX C Maintenance Notes ...
Page 52: ...52 4000599070 E11 16 USA GB Control Oil change Wheel reducer E002 15 mn Notes ...
Page 54: ...54 4000599070 E11 16 USA GB Replacement Hydraulic filter cartridge E003 15 min Notes ...
Page 56: ...56 4000599070 E11 16 USA GB Filling up Oil change Fuel tank E004 15 mn Notes ...
Page 64: ...64 4000599070 E11 16 USA GB Replacement Tightening Wheel E006 15 min Notes ...
Page 66: ...66 4000599070 E11 16 USA GB Tightening Screws bolts and nuts E007 15 min Notes ...
Page 72: ...72 4000599070 E11 16 USA GB Control Filling up Battery charge Battery E018 10 min Notes ...
Page 74: ...74 4000599070 E11 16 USA GB Changing glow plugs Glow plugs E030 30 mn Notes ...
Page 78: ...78 4000599070 E11 16 USA GB HA120PX D Diagnosis assistance Notes ...
Page 90: ...90 4000599070 E11 16 USA GB HA120PX E Electric circuit Notes ...
Page 100: ...100 4000599070 E11 16 USA GB HA120PX F Hydraulic circuit Proportional unit Diagram extract ...
Page 107: ...1 4000599070_USA_GB_e11 16 Electrical diagram HA120PX 1 HA120PX 1 1 FOLIO 1 7 ...
Page 108: ...2 Electrical diagram HA120PX 1 2 FOLIO 2 7 ...
Page 109: ...3 Electrical diagram HA120PX 1 3 FOLIO 3 7 ...
Page 110: ...4 Electrical diagram HA120PX 1 4 FOLIO 4 7 ...
Page 111: ...5 Electrical diagram HA120PX 1 5 FOLIO 5 7 ...
Page 112: ...6 Electrical diagram HA120PX 1 6 FOLIO 6 7 ...
Page 113: ...7 Electrical diagram HA120PX 1 7 FOLIO 7 7 ...
Page 114: ...8 Electrical diagram HA120PX ...
Page 116: ...2 HYDRAULIC DIAGRAM HA120PX ...