42
5.4.3.1. Stability test on H12SD.
The worst case overturning moment applied representing the least favorable loads and forces combined is:
Single extension:
Double extension:
2997 m.daN which is represented by a load of
310 kg applied as shown below with the elevating
work platform on a 5.5º side slope.
2722 m.daN which is represented by a load of
281 kg applied as shown below with the elevating
work platform on a 5.5º side slope.
Picture 14 : Simulation test on H12SD single
extension.
Picture 15 : Simulation test on H12SD double
extension.
5.4.3.2. Stability test on H15SD.
The worst case overturning moment applied representing the least favorable loads and forces combined is:
Single extension:
Double extension:
3306 m.daN which is represented by a load of
260 kg applied as shown below with the elevating
work platform on a 5.5º side slope.
2925 m.daN which is represented by a load of
230 kg applied as shown below with the elevating
work platform on a 5.5º side slope.
Picture 16 : Simulation test on H15SD single
extension.
Picture 17 : Simulation test on H15SD double
extension.