- Pre-operation inspection
HA32PX - HA100JRT - HA41PX-NT - HA130JRT-NT
A x l e e x t e n s i o n c o n t r o l b o x E - S t o p b u t t o n
4.2 - A
CTIVATION
OF
CONTROLS
The enable switch must be active to allow all movements.
The "Enable Switch" system depends on the machine configuration and will consist of one of
the following :
• Joystick trigger at platform panel (if fitted).
• Foot pedal switch in the basket.
• Enable switch at ground panel.
4.3 - F
AULT
DETECTOR
The machine is equipped with an on-board fault detection system, which indicates the type of
fault to the operator.
The fault is identified by a default code.
The default code is dispalyed at the ground control box.
According to the type of fault, the machine MAY switch into DOWNGRADEMODE and certain
movements are prevented to maintain Operator's safety.
Do not use the machine until the fault has been corrected.
4.3.1 - Indicators/LED's test
F r o m t h e g r o u n d c o n t r o l b o x
F r o m t h e p l a t f o r m c o n t r o l b o x
Step
Action
1
Pull the E-stop buttons( 15, 46, E5 ).
2
Set the ON/OFF key switch ( 18 ) to ON position.
3
Turn the control box activation selector switch ( 229 ) to the centre to activate the axle control box. The
indicators light up.
4
Push the E-stop button ( E5 ). The indicator goes out.
Step
Action
1
Pull both the E-Stop buttons ( 46 ) at platform panel and ( 15 ) at ground panel.
2
Set the ON/OFF key switch ( 18 ) to ON position.
3
Check that the LED's ( 1 - 10 ) light up on the display panel.
4
Check that the LED's on the display are all turned off after 1 sec.
Step
Action
1
Pull E-Stop button ( 15 ) at ground panel.
2
Turn the ON/OFF key switch ( 18 ) at ground panel to ON position.
3
Turn the energizing selector switch ( 229 ) to the left to energize platform control box.
4
First push in the E-Stop button ( 46 ) at platform panel, then pull out.
5
Check that the LED's ( 101 - 117 ) light up on the platform display panel.
6
Check that the LED's ( 101 - 117 ) on the display are all turned off after 1 sec.
Summary of Contents for HA100JRT
Page 2: ...2 4000328850 E 12 14 USA GB HA32PX HA100JRT HA41PX NT HA130JRT NT...
Page 8: ...8 4000328850 E 12 14 USA GB HA32PX HA100JRT HA41PX NT HA130JRT NT A Foreword Notes...
Page 22: ...22 4000328850 E 12 14 USA GB HA32PX HA100JRT HA41PX NT HA130JRT NT A Foreword Notes...
Page 118: ...118 4000328850 E 12 14 USA GB F Maintenance HA32PX HA100JRT HA41PX NT HA130JRT NT Notes...