52
4000327280
E09.16
USA / GB
HA120PX
D
- Operation instructions
2 - Ground control box
2.1 -
TO START THE MACHINE FROM THE GROUND CONTROL BOX
1.
Pull the E-stop button (15) : This will de-activate the state of E-stop button located in platform.
2.
Turn the key of the control box activation selector ( 72 ) to the right to energize the ground control
box. The following indicators light up :
• Electrical pre-heating (1).
• Low engine oil pressure (2).
• Engine temperature (3).
• Battery charge (4).
3.
The clogged air filter indicator ( 5 ) is switched off.
4.
For machines fitted with : Hold down the engine preheating selector ( 246 ) for a few seconds,
indicator ( 247 ) lights up.
5.
Press the starter push-button (22). The engine starts. The indicator goes out.
6.
Let the engine heat up.
To shut-down the machine from the ground control box :
• Turn the control box activation selector ( 72 ) key to the center.
• The machine is shut down. The power to the machine is switched off, all the indicators on the lower
console are off.
Summary of Contents for HA120PX
Page 1: ...Operator s manual HA120PX 4000327280 E09 16 USA GB Operator s manual HA120PX ...
Page 2: ...2 4000327280 E09 16 USA GB HA120PX ...
Page 6: ...6 Operator s manual ...
Page 38: ...38 4000327280 E09 16 USA GB HA120PX B Familiarization Notes ...
Page 70: ...70 4000327280 E09 16 USA GB HA120PX D Operation instructions Notes ...
Page 84: ...84 4000327280 E09 16 USA GB HA120PX E General Specifications Notes ...
Page 90: ...90 4000327280 E09 16 USA GB HA120PX F Maintenance Notes ...