92
4000827180
E 09.18
USA / GB
E
- General Specifications
HA12CJ - HA32CJ - -
5.1.4 - Pre-operation inspection
• If any item on the checklist is marked NO during the inspection; machine must be tagged and locked out
and placed out of service.
• DO NOT operate the machine until all identified items are corrected and it has been declared safe for
operation.
Description
Yes
No
Perform all specified machine functional tests
• All machine functional tests result positive
Start the machine from platform control box
Switch off (pushed in) all E-Stop buttons
• Check absence of warning signal
• Check that the light indicator is not activated when the machine is in
stowed position
To ensure Activ' Shield Bar device is functioning correctly, perform the following :
When stowed :
• Check that the green indicator light is not illuminated
When boom or arm is raised above 15° :
• Check that the green indicator light is illuminated
Simultaneously make a movement and push forward the activation bar to
trigger the system :
• Check that all movements stop
• Check that the horn and the blue flashing light are activated