121
4000414930
E 10.15
USA / GB
Electric
Battery (ies)
MS0051
When there is a fault, the LED indicator flashes in various colours depending on the type of alarm :
In case of an alarm, the charger stops supplying power
During charging :
• The machine's electric system is automatically deactivated while the external power supply is connected to the
machine
• Ensure that the battery are at a temperature not exceeding 45 °C(113 °F) (be careful in summer or in places with a
high ambient temperature)
• Do not remove or open the caps on the elements.
Charge interruption :
• To turn off the charger, disconnect it from the mains.
• Should the machine need to be operated during a charging cycle, first diconnect the charger. This may reduce the
life span of the batteries. Re-connect the charger once the operation is over.
After charging :
• Top up the electrolyte level, if necessary.
• Avoid overflowing.
• Wash the top of the batteries without removing the caps.
• Dry with compressed air or clean cloths.
• Oil the terminals.
State of flashing indicator
Type of alarm
Description (Action)
Red
Battery presence
Battery not connected or not compliant : Check connection or
rated voltage.
Yellow
Temperature probe
Temperature probe disconnected while charging or outside the
functional range : Check connection and measure battery
temperature.
Green
Specified time
Phase 1 or 2 is longer than the maximum allowed time : Check
battery capacity
Red-Yellow
Battery current
Loss of output current control : Faulty control logic.
Red-Green
Battery voltage
Loss of output voltage control : Battery disconnected or faulty
control logic.
Red-Yellow-Green
Temperature
Overheating of semiconductors : Check fan operation.
When the charger is connected to the mains for more than 48 h (hours), a new charging cycle starts up at
the end of the previous charging cycle in order to offset self-discharge.
Summary of Contents for STAR 10
Page 2: ...2 4000414930 E 10 15 USA GB STAR 8 STAR 22J STAR 10 STAR 26J ...
Page 10: ...10 4000414930 E 10 15 USA GB STAR 8 STAR 22J STAR 10 STAR 26J A Preface Foreword Notes ...
Page 18: ...18 4000414930 E 10 15 USA GB STAR 8 STAR 22J STAR 10 STAR 26J B Safety Notes ...
Page 32: ...32 4000414930 E 10 15 USA GB STAR 8 STAR 22J STAR 10 STAR 26J C Familiarization Notes ...
Page 62: ...62 4000414930 E 10 15 USA GB General data Breaking test procedure MS0004 Notes ...
Page 66: ...66 4000414930 E 10 15 USA GB General data Torque Values MS0005 Notes ...
Page 72: ...72 4000414930 E 10 15 USA GB Chassis and turntable Slew ring inspection MS0010 Notes ...
Page 80: ...80 4000414930 E 10 15 USA GB Electric Electrical wiring MS0059 Notes ...
Page 116: ...116 4000414930 E 10 15 USA GB Hydraulics Hydraulic filter cartridge Replacement MS0050 Notes ...
Page 124: ...124 4000414930 E 10 15 USA GB Electric Battery ies MS0051 Notes ...
Page 144: ...144 4000414930 E 10 15 USA GB Mast Inspection of the slack chain sensors MS0062 Notes ...
Page 148: ...148 4000414930 E 10 15 USA GB Overriding system Overriding function reset MS0085 Notes ...