Reach-In
P/N 0387183_V
2-9
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
MERCHANDISER ELECTRICAL DATA
Merchandiser data sheets for specific models are shipped
with this manual. The data sheets provide merchandiser
electrical data, standard electrical schematics, parts
lists and performance data. Refer to the merchandiser
data sheets and merchandiser serial plate for electrical
information. Refer to the separate wiring diagrams
shipped with the case for specific information about
the merchandiser and any optional wiring kits that
may have been applied.
FIELD WIRING
Field wiring must be sized for component amperes
stamped on the serial plate. Actual ampere draw may be
less than specified. Field wiring from the refrigeration
control panel to the merchandisers is required for defrost
termination thermostats and for optional refrigeration
thermostats. When multiple merchandisers are on the
same defrost circuit, the defrost termination thermostats
are wired in series.
ALWAYS CHECK THE
SERIAL PLATE FOR
COMPONENT AMPERES.
Electric Defrost is standard for low temperature
merchandisers and requires temperature termination.
Gas defrost is optional. Off Time Defrost is standard
for medium temperature merchandisers and is time
terminated.
When two or more merchandisers with full length
wireways are installed in line, remove the splashguards,
end caps and wireway covers, and install the nipple
and nuts (supplied) providing electrical passage from
one merchandiser to the next. Following NEC and
local codes is the responsi bility of the electrical
contractor.
ELECTRICAL CONNECTIONS
All wiring must be in compliance with NEC and local
codes. All electrical connections are to be made to
the terminal blocks in the electrical wireway behind
the lower front panel at the right-hand end of the
merchandiser (facing front).
IDENTIFICATION OF WIRING
Leads for all electrical circuits are identified by colored
plastic bands. These bands correspond to the color code
sticker (shown below) located inside the merchandiser
wireway.