63
Torx KA 3,5 x 32
min. 80 mm
> 75.000 Lux
E
R
E
E
R
R
E
R
2
5
3
4
6
20°
20°
± 10°
E
R
10°
40°
1
Due to the large optical aperture angle and the automatic calibration feature there is no alignment needed as
long as the light curtains are within the specified aperture angle, (fig. 2).
For installation of the light curtains please note ���
›that the emitter and the receiver profiles are not installed 180° turned to each other; that means, both
cables have to exit the profile in the same direction (fig. 1).
›that the profiles are not stretched or squeezed (fig. 4).
›that the fixing basis is flat enough.
›that the connecting cable is not exposed to tractive or shearing forces�
›that the cable is fixed and conduited safely and with large bending radius (fig. 3).
›to avoid dirt on the light curtains�
›to avoid contamination by oil or greasy fluids.
›that during operation, no sash, cable etc. extend into the surveillance field (fig. 5).
›to avoid interference with foreign infrared light sources like other light curtains, energy saving lamps, direct
sun light etc. at receiver curtain R (fig. 6).
›to clean the profiles with soap water, because solvents destroy them.
›to make sure that the operating range corresponds with the specification of the light curtain.
IMPORTANT WARNING:
This product is not a safety sensor to protect human life or human injury from dangerous parts of
machinery�
Notes for installation (continuation)
Other light sources
Mounting and Installation IR-light curtain (continuation)